Code
E-C3
Embroidering data buffer empty
E-C4
Presser foot down error
Measured voltage value could not be received form
E-C5
the lower shaft motor CPU.
Voltage value could not be transferred to the lower
E-C6
shaft motor CPU.
E-C7
Lower shaft error
E-C8
Hook motor origin point error
E-C9
Embroidering start error
E-CA
No sewing permission is given from PC.
E-CB
Spindle rotation speed error
E-CC
Shuttle thread entanglement automatic reset
E-CD
Speed command can not be received.
E-CE
Cylinder bed position error
Rated voltage value could not be received from the
E-CF
lower shaft motor CPU.
E-D0
Power PC board error
E-D1
Cooling fan motor stop B Tum the power off.
E-D2
Power voltage upper limit error
E-D3
Power voltage lower limit error
E-E1
X-axis pulse motor overcurrent stop
E-E2
Y-axis pulse motor overcurrent stop
E-E3
Cooling fan motor stop A Press R.
E-E4
Lower shaft communication error
E-E5
Over-run error during interfacing to main PCB CPU
E-E6
Framing error during interfacing to main PCB CPU
E-E7
Parity error during interfacing to main PCB CPU
Receiving time up error during interfacing to main
E-E8
PCB CPU
Error
BES-962BC • BES-1262BC
Is the IF cable disconnected? If it is connected normally, the cable or the
main board is faulty.
Press the
or turn on the F/B switch on the head to either side. If the
STOP
same error occurs again, adjust the presser foot switch.
This is not usually displayed.
The machine may be being tested in the BC test mode. Exit the test mode
or turn the power off and on once. If the same error occurs again, the main
PCB is faulty.
Check the operation of the main shaft brake and the stop position of the
main shaft (100 degrees).
The
is pressed while no sewing data has been transferred to the em-
broidery machine. Clear this error by the
necessary data from the machine controller and press the
This is not usually displayed.
Press the
or turn on the F/B switch on the head to either side to cancel
STOP
the error and press the
possibility that the spindle is overloaded.
This is not usually displayed.
Turn the power off and on once. If the same error occurs again, the main
PCB is faulty.
Secure the bed. If the bed is secured, the bed sensor position may be
faulty. Readjust it.
Turn the power off and on once. If the same error occurs again, the main
PCB is faulty.
Turn the power off and on once. If the same error occurs again, the power
PCB is faulty.
Turn off the power and check the fan harness. Turn on the power again. If
the same error occurs again, the fan or the power PCB is faulty.
(1) The voltage setting is improper. -> Set it again.
(2) Press the
or turn on the F/B switch on the head to either side. If
STOP
the same error occurs again, the power PCB or the power supply is
faulty.
Turn the power off and on once.
Turn off the power and check the fan harness. Turn on the power again. If
the same error occurs again, the fan or the power PCB is faulty.
Turn the power off and on once. If the same error occurs again, the main
PCB is faulty.
This is not usually displayed.

Chapter 11 Error code list

Measures
. To start sewing, transfer
STOP
. If the same error occurs again, there is a
.
249