RS232/485 interface

Options for using the serial interface include transparent data transfer, control of
connected devices or operation of the unit with a terminal program. Depending
on the setting, the serial interface uses the RS232 or RS244/285 standards. The
standard used depends on the current configuration (see page 56 and 87).
RJ45 connector pin assignment
The pin assignment depends on the standard used.
Pin
RS232 standard
1
RxD (receive data)
2
CTS (clear to send)
3
4
5
GND (ground)
6
7
TxD (transmit data)
8
RTS (ready to send)
Appendix
Installation and Operating Manual | VideoJet 8008
RS422/485 standard
RxD+ (receive data plus)
RxD- (receive data minus)
GND (ground)
TxD- (transmit data minus)
TxD+ (transmit data plus)
Bosch Security Systems | 2005-06 | V2.0