VideoJet 8008 | Installation and Operating Manual
Maintenance and upgrades

Testing the network connection

The ping command can be used to check the connection between two IP
addresses. This allows you to test whether a device is active in the network.
– Open the DOS command prompt.
– Type ping followed by the IP address of the device.
If the device is found, the response appears as " Reply from ... ", followed
by the number of bytes sent and the transmission time in milliseconds.
Otherwise, the device cannot be accessed via the network. This might be
because
The device is not properly connected to the network. Check the cable
connections in this case.
The device is not correctly integrated into the network. Check the
IP address, subnet mask and gateway address.

Restart (reset)

If necessary, you can restart the VideoJet 8008, for example if the unit is no
longer responding. All settings are retained.
– In the address bar of the web browser, enter /reset after the unit IP
address (for example 192.168.0.80/reset).
A new page appears containing the message going to reset Reconnecting in
... seconds, indicating the time until the connection will automatically be re-
established.