Sony DMW-S01NL Maintenance Manual page 33

Hide thumbs Also See for DMW-S01NL:
Table of Contents

Advertisement

LED
D6001 (green) : +2.5 V
Indicate +2.5 V power supply state
+2.5 V power supply voltage is made from
+3.3 V on the MTS-11 board.
Light on : Normalcy
Light off : Shut off +3.3 V power supply or
short +2.5 V lines circuit
D562 (green) : BD_NG
Light on : Normalcy
Light off : Abnormal power supply voltage
(some of +5 V, +3.3 V, +7 V,_7 V,
+15 V, +2.5 V) in the MTS-11 board
3. Audio control panel
CN304
S200
. CPU-315 board
Switch
S200 : Reset switch
Press this S200 when reset the CPU and their
peripheral circuit.
S300 (S300-1 to S300-4) : For design testing
Use the following factory setting
Factory setting
S300-1 to -4 : OFF of all
LED
D300 (green) : For design testing (Light off when normal operation)
D301 (green) : For design testing (Light off when normal operation)
D302 (green) : For design testing (Light off when normal operation)
D303 (green) : CPU operating status indication
Blinking at one second period during normal
operation
Connector
CN304 : Connector for RS232C testing
Factory use
DMW-S01NL/S02NL/ST001
S300
1-6. Switch and jumper-pin setting and LED functions
4. Trackball control panel
. CPU-316 board
COR201
COR200
COR101
CN102
Switch
S100 : Reset switch
Press this S100 when reset the CPU and their peripheral circuit
S102 (S102-1 to S102-4) : For design testing
Use the following factory setting
Factory setting
S102-1 to S102-4 : OFF of all
LED
D101 (green) : CPU operating status indication
Blinking at one second period during normal operation
D102 (green) : For design testing
D103 (green) : For design testing
D104 (green) : For design testing
Connector
COR101 : Connector for design testing
Factory use
COR200, COR201 : Connector for PLD writing
Factory use
CN102
: Connector for CPU program writing
Factory use
5. Media bar control panel
. CPU-319 board
S101
S102
D104
D103
D102
D201
Switch
S101 : Reset switch
Press this S100 when reset the CPU and their peripheral circuit
S102 (S102-1 to S102-4) : For design testing
Use the following factory setting
Factory setting
S102-1 to S102-4 : OFF of all
S100
S102
D101
D102
D103
D104
CN103
1-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dmw-s02nlDmw-st001Dmw-if02

Table of Contents