8.2 Typical Maintenance Standard (A) of Air Compressor...In case of annual run hour less than 6,000 hours
Maintenance part and item
Oil level gauge
Discharge air temp.
Relief valve
Lubricant (genuine synthetic oil)
Motor
Motor's cooling fin
Grease Reservoir
Mechanical seal
Air intake filter element
Oil filter element
Oil separator element
Solenoid valve
Cooling fans
DCBL controller cooling fan
Fan inverter
Motor
Electric panel, instruments, sensors Inspection/Cleaning
Pipe joints
Oil cooler, Aftercooler
Lubricant (genuine synthetic oil) Replacement
Oil level gauge
Consumable Parts Suction throttle valve ※ Replacement
Piston of minimum pressure valve / check valve ※ Replacement
Oil filling port O-ring, plug O-ring Replacement
Suction pipe
Oil temperature control valve
DCBL controller cooling fan
Fan motor bearing
Thermistor
Oil temperature control valve
Check valve (1/4 inch)
Coupling elastic body
O-ring (Air end)
O-ring (Flange)
O-ring, oil separator tank O-ring Replacement
DCBL motor bearing
Mechanical seal
Compressor Air end bearing
Controller smoothing capacitor
CPU printed circuit board,
power PCB
Fan inverter
※ Replace these parts every 2 calendar years or when the HISCREW has loaded/unloaded total 1,000,000 times,
whichever comes earlier. For the total load/unload times, watch the digital monitor.
8. PERIODIC MAINTENANCE [Maintenance Standards (A)]
Inspection time
Check
Daily 1-Month 6-Month 1-Year 2-Year 4-Year 8-Year
Oil level check
Discharge air temp. check ○
Performance check
Replenish/
(○)
Analysis
Greasing
Cleaning
Cleaning
Oil leak check
Replacement
Replacement
Replacement
Performance check
Crack check/Cleaning
Crack check/Cleaning
Crack check/Cleaning
Insulation check
Loose check
Cleaning
Replacement
Replacement
Inspection/Cleaning
Replacement
Replacement
Inspection
Replacement
Replacement
Replacement
Replacement
Replacement
Replacement
Replacement
Replacement
Replacement
Check/Clean/Replace
Replacement
Oil level must be within red lines during operation.
Must be between 65℃ and 100℃.
Check by hand.
Replenish every 1,000 to 1,500 hours
Sampling analysis every 3,000 hours
Use "RMS Grease"
Clean once for every 2 grease replenishments.
If the oil leak is 3 cc/h or higher, replace the seal even
before 8-year (48,000 hours) operation.
Clean if the error code of an element clogging
appears on the digital monitor. Replace whenev-
er the number of times of cleaning has reached
5 times even within one year interval.
Replace the housing and square ring as well.
Clean cooling fins and duct.
1M ohm or more at DC500 V Mega.
Terminal refastening, electric line cover check and cleaning.
Replace the cap seal, valve plate, and O-ring.Clean.
Replace check valve spring, O-ring at the same time.
Change O-ring.
Including cooling fan in the starter/control box.
If not so, clean it and continue to use it.
Locate it on the oil-scavenging pipe from the shaft seal.
If not so, clean it and continue to use it.
Replace 1/2 stop valve O-ring at the same time.
If it is dirty or shows a change in color, replace it.
If not so, clean it and continue to use it.
Reference
Note
page No.
20
18
45
20,21
52
52
52
47
46
50
53
21
49
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hiscrew v plus osp-55vanHiscrew v plus osp-75van