Hitachi HISCREW V PLUS NEXT Series Instruction Manual page 28

Oil-flooded rotary screw air compressor
Table of Contents

Advertisement

5. TROUBLESHOOTING [SHUTDOWN/ALARM Indications on the Instrument Panel]
■ How to Check Cause of Shutdown When E0.13 (Controller Abnormality) and E0.57
(Fan Inverter Abnormality) and Shutdown History in DCBL Controller and Fan Inverter
Discharge air pressure display
SWITCH DISPLAY
Press 14 times.
显示转换
Increments by 1 
each time pressed
重新设定
Returns to 
discharge 
air pressure 
display
2
Decrements by 1 
each time pressed
(a) DCBL Controller shutdown code
Code
Shutdown contents
E01
Software
Overcurrent
protection
E02
Hardware
E05
Overload protection
E07
Overvoltage protection
E09
Voltage defi ciency protection Below specifi ed voltage
E10
CT error
E20
Temperature trip
E21
Temperature trip
E22
Communication error 1
E23
Gate array error
E24
Phase-lacking connection protection Input phase-lacking connection
E30
IGBT error
E33
Communication error 2
E35
Motor overheat
(b) Fan inverter shutdown code
Code
Shutdown contents
E01
Fixed speed
E02
Overcurrent
Deceleration
protection
E03
Acceleration
E04
Other
E05
Overcurrent protection
E07
Overvoltage protection
E08
EEPROM error
E09
Voltage defi ciency protection Below specifi ed voltage
E11
CPU error
E14
Short-circuit protection
E15
Receiving overvoltage
E21
Temperature trip
E23
Gate array error
E60
Communication error
※ Retry operation target item
26
Shutdown history of 
DCBL controller
Shutdown history of 
fan inverter
To various setting status display
Detection
Current protection circuit trip
Electronic thermal trip
Over specifi ed converter voltage
Built-in CT abnormality
DCBL Controller fan abnormality
Cooling fi n overheat
DCBL Controller internal communication abnormality Outside noise
Gate array communication abnormality
Generation of instantaneous overcurrent
Communication abnormality between DCBL controller and control board Outside noise
Motor overheat
Detection
Current protection circuit trip
Electronic thermal trip
Over specifi ed converter voltage
Abnormal data in EEPROM
Built-in CPU abnormality
Short-circuit when power turned on
Over specifi ed voltage
Temperature abnormality
Gate array communication error
Communication abnormality between inverter and CPU printed curcuit board
① Press the SELECT switch 14 times. "E6" and "E7" are
shutdown histories of the DCBL controller. 5 of "E5." indi-
cates the oldest display of the digital monitor.
② Press the RESET button. The screen returns to the usual
digital monitor display.
IMPORTANT
1. If the shutdown code "XX" is "
no shutdown history. When other than shutdown
history displayed without performing shutdown
reset, it returns to the newest shutdown history dis-
play 3 minutes later.
2. The shutdown histories of the DCBL controller and
the fan inverter are recorded for the latest shutdown
only. The shutdown code displays a dedicated code.
(
See shutdown code on this page.)
Motor restraint
Sudden acceleration
Motor overload
High receiving voltage
Receiving voltage drop, instantaneous power interruption
DCBL Controller fan rotation drop, DCBL controller fan wire break
Cooling fi n, suction hole, cooler clogging, high ambient temperature
Cooling fi n, suction hole, cooler clogging, high ambient temperature
Motor restraint
Sudden acceleration
Motor overload, restart immediately after stopping
High receiving voltage
Outside noise, temperature rise
Low receiving voltage
Between output section and motor
Receiving voltage higher than specifi cation voltage
Cooling fi n, suction hole, cooler clogging, high ambient temperature
Communication line break, outside noise
" it means there is
Cause
Cause