Amplifier Location Selection; Figure 2-1 Front Panel - Ergonomic Position With Tilt Foot Bar - Acom 1200S Installation, Operation And Maintenance Manual

1.8-54 mhz linear power amplifier
Hide thumbs Also See for 1200S:
Table of Contents

Advertisement

User's Manual | ACOM 1200S | 1.8-54 MHz Linear Power Amplifier

Amplifier Location Selection

2.3.
The weight of the unit is about 16 kg, which should preferably be handled by two
persons.
Position the amplifier near the place where it will be used. You will need an easy access to the command
buttons on the front panel, as well as to the rear panel cabling.
The ACOM 1200S is forced air cooled. Keep a minimum clearance distance of 10 cm
(4 inches) to any other devices or objects.
The exhaust air can reach 65
or use forced air cooling themselves, increase the distances accordingly.
Do not leave accidental paper, cloth or other lightweight pieces around and under the
amplifier. They may be drawn in by the cooling air stream and block the vents. This will
lead to overheating and accelerated material aging, not covered by the warranty.
August 2021
o
o
C (150
F) and if the surrounding devices are sensitive to heating from outside

Figure 2-1 Front panel - Ergonomic position with tilt foot bar

Figure 2-1 Front panel - Ergonomic position with tilt foot bar
CAUTION
NOTICE
NOTICE
S e c t i o n INSTALLATION | Page 15 of 60