Verifying the Installation

To verify the hardware installation, observe the following indicators:
T
T
T
If these status indicators fail to appear as described, see
and
8610-A2-GN20-10
The PWR A and/or PWR B LEDs on the front panel must be in the ON state
(green):
— If you are using a single –48 VDC power source, then only the green
PWR A LED will be ON.
— If you are using dual VDC power sources, then both the green PWR A and
PWR B LEDs will be ON.
— If you are using a single AC power source, then the green PWR A LED
must be ON.
— If you are using both an AC power source and a –48 VDC power source,
then both the PWR A and PWR B LEDs must be ON.
The yellow FAN ALM LED on the front panel must be OFF.
Also check the SYSTEM LEDs on the MCP and DSL cards if you have not
done so already. The OK SYSTEM indicators on the cards must be in the ON
state (winking green).
LEDs
in Chapter 4, Troubleshooting , for more information.