2. Installation

Interconnecting 8610 Systems

Procedure
To interconnect multiple Hotwire 8610 systems:
The following illustration shows the designated number for each DSL card slot in a
stack.
2-6
1. Connect the end of an 8-pin modular cable into the Management OUT port of
the base chassis.
2. Dress the 8-pin modular cable to the left and under the chassis, behind the
foot, and up the side of the unit.
3. Plug the other end of the 8-pin modular cable into the Management IN port of
the 8610 chassis above, dressing the cable as in the previous step.
4. Repeat for the next 8610 chassis, connecting the Management OUT port of
Chassis 2 to the Management IN port of Chassis 3.
NOTE:
Bus cables must use Unshielded Twisted Pair (UTP) CAT5 cable. The total bus
cabling should not exceed 25 feet.
NOTE:
This illustration shows a stack of six Hotwire 8610 systems, which is valid for
rack mounting. However, the same relationship of software-assigned slot
numbers applies to two stacks of three each, mounted on a desk or tabletop
and connected by a bus cable. The base chassis must still have the MCP card
in physical Slot 1 with the base chassis Stack Position switch set to 1. The
software does not assign a slot number to the MCP card.
ESD
ESD
MCP/
DSL
DC FUSES
48VDC CLASS 2
T4A, MIN. 48V
OR LIMITED
FAN
PWR SOURCE
AC
ALM
A
INPUT
A
B
A B
A
B
48V
RTN
ESD
ESD
MCP/
DSL
DC FUSES
48VDC CLASS 2
T4A, MIN. 48V
OR LIMITED
FAN
PWR SOURCE
AC
ALM
A
INPUT
A
B
A B
A
B
48V
RTN
ESD
ESD
MCP/
DSL
DSL
DC FUSES
48VDC CLASS 2
T4A, MIN. 48V
OR LIMITED
FAN
PWR SOURCE
AC
ALM
A
INPUT
A
B
A
B
A B
Cards
48V
RTN
ESD
ESD
MCP/
DSL
DC FUSES
48VDC CLASS 2
T4A, MIN. 48V
OR LIMITED
FAN
PWR SOURCE
AC
ALM
INPUT
A
B
A
A
B
A B
48V
RTN
ESD
ESD
MCP/
DSL
DC FUSES
48VDC CLASS 2
T4A, MIN. 48V
FAN
OR LIMITED
PWR SOURCE
AC
ALM
A
INPUT
A
B
A B
A
B
48V
RTN
MCP
ESD
ESD
MCP/
Card
DSL
DC FUSES
48VDC CLASS 2
T4A, MIN. 48V
OR LIMITED
FAN
PWR SOURCE
AC
ALM
A
INPUT
A
B
A B
A
B
48V
RTN
April 2001
Assigned DSL Slot Numbers
Physically
Assigned
3
3
2
2
1
1
MANAGEMENT
10/100 BASE T
PWR
5
4
6
3
2
1
B
STACK
IN
OUT
SERIAL
ALM INTF
2
3
MCP/1
POSITION
3
3
2
2
1
1
MANAGEMENT
10/100 BASE T
PWR
5
4
6
3
2
1
B
STACK
IN
OUT
SERIAL
ALM INTF
MCP/1
2
3
POSITION
3
3
2
2
1
1
MANAGEMENT
10/100 BASE T
PWR
4
5
6
3
2
1
B
STACK
IN
OUT
SERIAL
ALM INTF
MCP/1
2
3
POSITION
3
3
2
2
1
1
MANAGEMENT
10/100 BASE T
PWR
4
5
6
3
2
1
B
STACK
IN
OUT
SERIAL
ALM INTF
MCP/1
2
3
POSITION
3
3
2
2
1
1
MANAGEMENT
10/100 BASE T
PWR
4
5
6
3
2
1
B
STACK
IN
OUT
SERIAL
ALM INTF
MCP/1
2
3
POSITION
3
3
2
2
1
1
MANAGEMENT
10/100 BASE T
PWR
5
4
6
3
2
1
B
STACK
IN
OUT
SERIAL
ALM INTF
MCP/1
2
3
POSITION
Software
Assigned
17
16
15
14
13
12
11
Additional
10
Systems
9
8
7
6
5
4
3
2
Base
1
Chassis
00-16313-02
8610-A2-GN20-10

Advertisement

Table of Contents
loading

Table of Contents