Internal Or External Controling (Sen) - RADEMACHER DuoFern 9433-1 Translation Of The Original Installation And Commissioning Manual

Radiator actuator 2
Hide thumbs Also See for DuoFern 9433-1:
Table of Contents

Advertisement

10.6 Internal or external controling (SEn)

Factory setting = OFF
This menu is only visible in connection with a DuoFern Room
Thermostat 2. Optionally, the measured actual (IST) temper-
ature of a DuoFern Room Thermostat 2 can be used as the
controlled variable of the DuoFern Radiator Actuators 2.
This can be useful, for example, if the DuoFern Radiator
Actuators 2 are mounted in a niche and the temperature
detection is not sufficient there.
i
i
24
The temperature determined by the DuoFern
Radiator Actuator 2 itself is used for control.
The temperature determined by the DuoFern
Room Thermostat 2 is used for control.
The DuoFern Room hermostat 2 should be in the
same room as the DuoFern Radiator Actuator 2.
The quality of the regulation depends on the
reception interval (see chapter 10.8, page 26).