ALARMS

If any alarms appear during initial startup, read the instructions provided in the following table. If the solution is not
possible, immediately contact the Manufacturer to request technical support.
In the meantime, do not try to repair or use the minipool but rather disconnect it from the electricity and water
supplies.
ALARMS
Screen
NOTIFICATIONS
displayed
Temperature
alarm
(notification)
Temperature
sensor alarm
(alarm)
FLOW ALARMS
Flow alarms keep the heater from operating in potentially hazardous conditions. Upon activation of the recirculation
pump, the flow switch must signal the presence of flow within five seconds.
There are two types of alarms related to flow: no flow or flow switch failure:
No flow alarm
(notification)
Water level alarm
(notification)
PROBLEM
Water leaks
The water of the minipool does not
become clear
DESCRIPTION OF THE PROBLEM
POSSIBLE SOLUTIONS
Problem description: if the water temperature in the minipool exceeds
42°C all the functions are deactivated, the display shows the "HI" message
HI
alternating with the temperature value.
Solutions: the alarm and the system will automatically reset when the
temperature drops. If the alarm does not reset contact the Manufacturer.
Problem description: a temperature sensor measures the water
temperature inside the minipool, activating the heater when necessary.
The allowed water temperatures range from 5°C to 45°C. Values outside
the range cause the blocking of all functions and the permanent activation
of the alarm message.
Solutions: the alarm will reset automatically once the temperature
ER
returns to allowed values (5° to 45°). The message is also displayed if
the temperature sensor malfunctions.
Solutions: make sure that the water temperature is not outside of the
permitted values, try to disconnect the power supply to the bathtub
and switch it on again after 30 seconds. If the problem persists, verify
that the connection with the control unit is correct and has not been
tampered with. Otherwise contact the Manufacturer.
Problem description: When the recirculation is active but the flow
switch does not detect flow for five continuous seconds, the heater is
disabled, the recirculation pump remains active for five minutes, after
FL
which it switches off, the display shows the message "FL" alternating
with the temperature.
Solutions: turn off the bathtub and clean the filters. Make sure that the
recirculation pump works perfectly. Otherwise contact the Manufacturer.
Problem description: If the level sensor does not detect water for more
than three consecutive seconds, the water level alarm is generated. All
loads (water pumps, blowers, recirculation pump, heater and ozonator)
LL
except for the light are disabled, the display shows the message "LL"
alternating with the water temperature. The alarm is automatically reset
as soon as the level is restored.
Solutions: add water to the minipool.
POSSIBLE CAUSE
Some component is probably not fully
tightened or the seals are worn.
Most likely the pH of the water supply
is incorrect and so algae grows.
For more information see
chapter "Water treatment" on
page 20
Muse - Maya - Wave
EN
SOLUTION
Check the tightness or replace the
seals.
Use disinfectants.
Remember that the paper filter does
NOT block metal oxides that may
over time damage components of the
minipool.