Install the PA-220 Firewall on a Flat Surface..............20 Install the PA-220 Firewall on a Wall...................21 Install the PA-220 Firewall in a 19-inch Equipment Rack..........23 Install the PA-220 Firewall Using the PAN-PA-220-RACKTRAY....... 23 Install the PA-220 Firewall Using the PAN-PA-220-RACK-SINGLE....27 Connect Power to a PA-220 Firewall............
Before You Begin Read the following topics before you install or service a Palo Alto Networks next- ® generaon firewall or appliance. The following topics apply to all Palo Alto Networks firewalls and appliances except where noted. > Upgrade/Downgrade Consideraons for Firewalls and Appliances >...
First Supported Soware Release: PAN-OS ® The following topics describe the hardware features of the PA-220 firewall. To view or compare performance and capacity informaon, refer to the Product Selecon tool.
PA-220 Firewall Overview PA-220 Front Panel The following image shows the front panel of the PA-220 firewall and the table describes each front panel component. Item Component Descripon Ethernet ports Eight RJ-45 10/100/1000Mbps ports for network traffic. You can set the link speed and duplex or choose auto- negoate.
PA-220 Firewall Overview PA-220 Back Panel The following image shows the back panel of the PA-220 firewall and the table describes each back panel component. Item Component Descripon Power adapter inputs Use the power inputs to connect power to the firewall.
Install the PA-220 Firewall The PA-220 next-generaon firewall ships with the hardware required to install the firewall on a flat surface or on a wall. You can also order a rack mount kit to > Install the PA-220 Firewall on a Flat Surface >...
Install the PA-220 Firewall Install the PA-220 Firewall on a Flat Surface Aach the rubber pads to the recessed circles on the boom of the firewall and then place the firewall on a flat stable surface. PA-220 Next-Gen Firewall Hardware Reference 2021 Palo Alto Networks, Inc.
Install the PA-220 Firewall Install the PA-220 Firewall on a Wall Install a PA-220 firewall on a drywall or plywood wall using the wall-mount kit as describe in the following procedure. STEP 1 | If the four rubber pads are installed on the boom of the firewall, remove them.
Page 22
Connect the second power adapter through a different circuit breaker to provide power redundancy and allow for electrical circuit maintenance. The following image shows a completed installaon for a PA-220 firewall with only a single power adapter. PA-220 Next-Gen Firewall Hardware Reference 2021 Palo Alto Networks, Inc.
The PA-220 firewall one-unit (1U) rack tray kit (PAN-PA-220-RACKTRAY) enables you to install one or two PA-220 firewalls in a two-post 19" rack. The installaon hardware (screws and brackets) for the le side of the tray is contained in bags. The installaon hardware for the right side of the tray is pre-installed.
Page 24
Install the PA-220 Firewall STEP 3 | Install the PA-220 power adapter in the power adapter bracket and secure it with the Velcro strap. (Oponal): Install a second power adapter for redundancy. STEP 4 | Slide the firewall (with power adapter bracket) into the rack tray and aach the rack tray brackets to the rack tray using one 4-40 x 1/4”...
Page 25
STEP 7 | With the help of another person, hold the assembled PA-220 firewall rack tray in place in the equipment rack and secure the rack tray brackets to the front rack posts using a #2 Phillips- PA-220 Next-Gen Firewall Hardware Reference 2021 Palo Alto Networks, Inc.
Page 26
(#10-32 x 3/4” or #12-24 x 1/2”) and torque to 25 in-lbs. Use cage nuts to secure the screws if the rack has square holes. PA-220 Next-Gen Firewall Hardware Reference 2021 Palo Alto Networks, Inc.
Install the PA-220 Firewall Install the PA-220 Firewall Using the PAN-PA-220-RACK-SINGLE STEP 1 | Align the back of the firewall with the two tabs located on the rack mount. STEP 2 | Use two #4-40 X 1/4” screws to aach the back of the firewall to the two tabs from Step 1.
Connect Power to a PA-220 Firewall The PA-220 firewall is powered by an external power adapter that converts an AC power source to DC power. The firewall can operate with one power adapter or you can install a second power adapter for power redundancy.
Connect Power to a PA-220 Firewall How to Connect Power to a PA-220 Firewall The following procedure describes how to connect power to a PA-220 firewall. To avoid injury to yourself or damage to your Palo Alto Networks hardware or the data ®...
Service the PA-220 Firewall Hardware The following topics describe how to interpret the PA-220 status LEDs and how to replace a PA-220 power adapter. The power adapter is the only serviceable component on the PA-220 firewall. > Interpret the LEDs on a PA-220 Firewall >...
Service the PA-220 Firewall Hardware Interpret the LEDs on a PA-220 Firewall The following table describes how to interpret the status LEDs on the PA-220 firewall. Descripon Front Panel LEDs HA (High • Green—The firewall is the acve peer in an acve/passive Availability) configuraon.
Page 35
Service the PA-220 Firewall Hardware Descripon If you configure the link state to down on a port, the LEDs on some acve ports will not work. Similarly, if the passive link state is set to shutdown, the HA link LEDs on the passive device in the HA pair will not work.
Replace a Power Adapter on a PA-220 Firewall The PA-220 firewall can operate on one power adapter or you can install a second power adapter for power redundancy. If two power adapters are installed and one fails, you can replace the failed power adapter without interrupon.
firewall. If the rubber feet are installed on the boom of the firewall, add .78” (2cm) to the height.Rack units and dimensions if the PA-220 firewall is installed in the PA-220 19” rack kit. • Rack units—1U •...
The following table describes PA-220 firewall electrical specificaons. Specificaon Value Power adapter The PA-220 firewall operates on DC power that is provided by the external power adapter (provided). The firewall can operate on one power adapter or you can install a second power adapter for power redundancy.
32°F to 104°F (0° to 40°C) Non-operang temperature -4°F to 158°F (-20° to 70°C) Humidity tolerance 5% to 90% non-condensing Airflow The PA-220 firewall uses passive cooling and does not contain fans. Maximum BTUs/hour 102 BTUs/hour Acousc noise Emits no sound.
PA-220 Firewall Specificaons Miscellaneous Specificaons The following table describes PA-220 firewall miscellaneous specificaons. Specificaon Value Storage capacity One 32GB SSD for system files and log storage. Mean me between failures (MTBF) 29 years PA-220 Next-Gen Firewall Hardware Reference 2021 Palo Alto Networks, Inc.
Our products meet standards for product safety and electromagnec compability when used for their intended purpose.To view compliance statements for the PA-220 firewall, see PA-220 Firewall Compliance Statements...
PA-220 Firewall Compliance Statements Overview PA-220 Firewall Compliance Statements The following lists the PA-220 firewall hardware compliance statements: • VCCI: This secon provides the compliance statement for the Voluntary Control Council for Interference by Informaon Technology Equipment (VCCI), which governs radio frequency emissions in Japan.The following informaon is in accordance to VCCI Class B requirements:...
Page 45
PA-220 Firewall Compliance Statements Overview determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separaon between the equipment and receiver.