Environmental Testing

Test Method
MIL-STD-810G,
Test method 514.6
IEC 60068-2-64
MIL-STD-810G,
Test method 516.6
SAE J1455 for
heavy-duty vehicles
MIL-STD-810G,
Test methods
501.5, 502.5
MIL-STD-810G,
Test methods
501.5, 502.5
MIL-STD-810G,
Test method 507.5
IEC 60529
IEC 61000-4-2
Rev. 6 October 2021
LDAP
RADIUS
TACACS+
Event Types: digital input, GNSS/AVL, network parameters,
data usage, timer, power, gateway temperature
Report types: SMS, email, SNMP trap, relay output, GNSS RAP
reports, Events Protocol Message to Server
Category
Description
Vibration
Frequency range: 10 Hz–150 Hz
Spectrum level: 2.24G on all axes for 8 hours/axis
Operating mode: powered on
Mechanical Shock Half-sine 40G, 15–23 ms,
(+/-X, +/-Y, +/-Z directions, 10 times per axis)
Operating mode: powered on
Shock and
Vibration: Section 4.10.4.2 Cab Mount
Vibration
Shock: Section 4.11.3.4 Operational Shock
Temperature
Rugged category: -30 °C to 70 °C
2-hour soak each temp high/low 3 cycles
ramp <= 3 °C/minute
Operating mode: powered on
Temperature
Rugged category: -40 °C to 85 °C
2-hour soak each temp high/low 50 cycles
ramp <= 3 °C/minute
Operating mode: unpowered
Humidity
10 × 48-hour cycles:
4-hour ramp to 60 °C (95% humidity), hold 8 hours
4-hour ramp down to 30 °C (85% to 95% relative
humidity), hold 21 hours
1-hour ramp down to 20 °C, hold 4 hours
1-hour ramp up to 30 °C, hold 5 hours
Operating mode: powered on
Water
Subject to spraying water. Water sprayed at an angle up
a
Resistance
to 60° on either side of the vertical for 10 minutes.
Operating mode: unpowered
Electrostatic
+/-2 kV, +/-4 kV, +/-6 kV, +/-8 kV (Contact and Air)
Discharge
+/-15 kV (Air at antenna connector)
Operating mode: powered on