X10 Siren And Lamp Module Functions; Emergency Planning - GE Simon 60-875 Installation Instructions Manual

Hide thumbs Also See for Simon 60-875:
Table of Contents

Advertisement

Note
The X10 Siren must be set
to unit #9 to "hear" emer-
gency alarms and Status
Beeps. To "hear" emer-
gency alarms only, set to
unit #10.
Emergency
Planning
66
Keychain Touchpad: Press the LIGHT button repeatedly to turn all lights on and
off. The panel responds with Lights on/off.
Remote Handheld Touchpad/QS1500 Keypad: Press the Lights On button and
the unit # of the lamp module using the numeric buttons to test individual lamp
modules 1 - 8. The panel responds with Lights # on/off. Pressing the Lights On or
Off button twice, turns all the lights on or off.

X10 Siren and Lamp Module Functions

All sirens turn off when the system is disarmed or when the siren timeout expires. Siren
priority is as follows:
1.
Fire (highest priority)
2.
Intrusion
3.
Emergency
If an alarm of greater priority occurs during an alarm of lower priority, the greater prior-
ity alarm sirens sound. Fire alarms sound a temporal 3 pattern (0.5 seconds on, 0.5 sec-
onds off for three beeps then 1.5 seconds off).
Alarm Siren and X10 Light Information
X10 Lights
X10 Siren
Interior & Panel Siren
Exterior Siren
Emergency Planning Floor Plan
Use these guidelines when drawing an emergency floor plan for the homeowner:
Show all building levels.
Show exits from each room (2 exits per room are recommended).
Show the locations of all security system components.
Show the locations of any fire extinguishers.
Fire
Intrusion
Steady
Flashing
Steady
Steady
Temporal 3
Steady
Temporal 3
Steady
Emergency
Steady
Alarm beeps
Fast on/off
Simon Security System

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simon 60-910Simon 600-1012

Table of Contents