Note
These option settings are in
addition to UL 1023 and 985
and are required only if the
system is set up for Central
station reporting.
Note
UL requirements take prior-
ity over SIA requirements.
Opt.
Function
#
10
Entry Delay
11
Exit Delay
17
Dialer Delay
38
Auto Arm
45
Sensor Alarm
Restoral Report
52
Unvacated
Premises
56
Call Waiting
59
Exit Extension
68
Swinger Shutdown
69
SIA Limits
86
Fire Alarm Verify
2
Option 29: Control Panel Alarms set to on
Option 39: Siren Timeout set to 4 minutes or more
Option 40: Trouble Beeps set to on
Option 50: RF Jam Detect set to on
Option 53: Hardwire Siren Supervision set to on if Option 29: Control Panel
Alarms is set to off
Option 85: Smoke Supervision must be set to on
UL 1023 & 985 24-Hour Backup
For 24-hour backup, the total current draw for all connected devices is limited to 25
mA (during normal standby conditions) using a 1.2 AH battery.
UL 1635 Digital Alarm Communicator System
Same as UL 1023 & 985, plus:
Option 12: Phone 1 Reports set to 0 or 1
Option 16: Auto Phone Test set to 001
Option 19: RF Timeout set to less than 4 hours
Option 24: AC Power Failure Report set to on
Option 25: CPU Low Battery Report set to on
Option 26: Fail to Communicate set to on
Option 50: RF Jam Detect set to on
Option 10 and 17: Entry Delay plus the Dialer Delay must not exceed 60 seconds

SIA System Requirements

SIA system requirements are the same as those described for a UL Listed Basic System
on page 1, plus:
If multiple annunciation is required, use Hardwire Siren part no.13-046.
SIA Setting Requirements
The following table describes programming requirements to meet ANSI-SIA CP-01.
Programming
Testing Page
Page Reference
Reference
26
27
29
37
40
42
44
45
48
48
54
Default
Setting
58
30 sec.
58
60 sec.
58
30 sec.
58
On
58
Off
58
On
58
Off
station and customer has call
58
On
58
On (one
trip)
58
On
58
Off
Required Setting
30-254 sec.
45-254 sec.
15-45 sec.
On
3
On
On if reporting to central
waiting service
On
On (one trip)
On
On
Simon Security System