Option 67: Quick Exit; Option 68: Swinger Shutdown; Option 69: Sia Limits - GE Simon 60-875 Installation Instructions Manual

Hide thumbs Also See for Simon 60-875:
Table of Contents

Advertisement

Option 67: Quick Exit

Determines whether pressing the Disarm button when
the system is armed activates the exit delay time to
allow exit and re-entry without disarming the system
(on) or not (off).
This feature is useful if the user wants to step outside
briefly and return, such as to get the paper. If the sys-
tem is armed and the user presses the Disarm button,
the panel announces "Exit time on" and sounds exit
delay beeps. This allows a designated entry/exit door
to be open for up to 2 minutes without causing an
alarm. When the door is closed, the beeps stop and the
door is armed again.
Note
For UL listed systems, Quick Exit must be off.

Option 68: Swinger Shutdown

Determines whether the panel prevents the same sensor
from activating an alarm more than once in a single
arming period (on) or not (off).
Note
Swinger Shutdown does not affect smoke and fire sensors.

Option 69: SIA Limits

Determines whether Entry, Exit, and Dialer delay times
fall within SIA limits (on) or factory ranges (off).
The table below shows the available settings when this
option is on or off.
Note
If options 10, 11 or 17 are set outside the SIA limits while
Option 69 is OFF, turning Option 69 ON will not affect
options 10, 11 or 17 until they are manually changed.
Not investigated for use by UL.
Note
When this option is off, there are no CS reports for sensor
tests.
48
¾ To turn on Quick Exit, press:
1. Add
2.
Option #
3.
67
4.
DONE
¾ To turn off Quick Exit, press:
1.
Delete
2.
Option #
3.
67
4.
DONE
¾ To turn on Swinger Shutdown, press:
1. Add
2.
Option #
3.
68
4.
DONE
¾ To turn off Swinger Shutdown, press:
1.
Delete
2.
Option #
3.
68
4.
DONE
¾ To turn on SIA Limits, press:
1. Add
2.
Option #
3.
69
4.
DONE
¾ To turn off SIA Limits, press:
1.
Delete
2.
Option #
3.
69
4.
DONE
Affected Option
Option 10: Entry Delay
SIA Limits
SIA Limits
Factory Ranges
(Option 69 on)
(Option 69 off)
030-254 seconds
005-254 seconds
(Default = off)
(Default = on)
(Default = on)
Simon Security System