Option 73: Modem Sensitivity

Determines whether the modem sensitivity is set
to normal (off) or high (on).
Note
This feature should be used only if the panel experi-
ences consistent trouble reporting to the central sta-
tion. Otherwise, leave this option off.

Option 74: Silent Panel Police Panic

Determines whether pressing the panel police
panic button causes an audible (off) or silent (on)
alarm.
Note
For UL Listed systems, this option must be off (audi-
ble).

Option 75: VOX Mic Gain

Sets the mic gain (sensitivity) that triggers the
voice-activated switching (VOX).
Room size, acoustics, and furnishings where
the panel or Interrogator 200 are located will
influence the setting. The available settings
are 01 (low) - 64 (high). Entries must be 2 dig-
its.
For panels with a built-in microphone, a set-
ting of 14 is recommended. For systems using
the Interrogator 200, a setting of 7 should be
used.
50
¾ To turn on Modem Sensitivity, press:
1. Add
2.
Option #
3.
73
4.
DONE
¾ To turn off Modem Sensitivity, press:
1.
Delete
2.
Option #
3.
73
4.
DONE
¾ To turn on Silent Panel Police Panic, press:
1. Add
2.
Option #
3.
74
4.
DONE
¾ To turn off Silent Panel Police Panic, press:
1.
Delete
2.
Option #
3.
74
4.
DONE
¾ To set VOX Mic Gain, press:
1. Add
2.
Option #
3.
75
4.
Use the numbered keys to enter 01 - 64 (entries must be 2 digits).
5.
DONE
¾ To reset VOX Mic Gain (return to default), press:
1.
Delete
2.
Option #
3.
75
4.
DONE
(Default = off)
(Default = off)
(Default = 14)