Annual service and maintenance

We recommend having your fi replace serviced every year. Contact your dealer quoting the model number. It will
be helpful if the fi replace's serial number can also be quoted. These numbers are on the information card (see
page 7).
A list of replacement parts is included in your fi replace Installation Manual. Please always quote the part number
and description when requesting spare parts.
Annual Inspection
Maintain the safe operation of your fi replace. Contact your dealer to have a qualifi ed technician go over the list
below and make the necessary verifi cations at least once every year.
Safe Operation List: to be performed by a qualifi ed technician only.
 Inspect and operate the pressure relief mecha-
nism to verify relief mechanisms are free from
obstruction to operate. See Cleaning Your Fire-
place section of this manual.
 Clean glass window with a suitable fi replace
glass cleaner. Abrasive cleaners must not be
used. Be careful not to scratch the glass when
cleaning. See Cleaning Your Fireplace section of
this manual.
 Inspect the operation of the fl ame safety sys-
tem Pilot or Flame rectifi cation device.
 Inspect and make sure the lighting of the main
burner occurs within 4 seconds of the main
gas valve opening. Visual inspection should
match that outlined in the appliance instruc-
tion manual. Inspect primary air openings for
blockage. See Checking Pilot and Burner Flame
section of this manual.
 Caution
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.
12
 Inspect condition of vent and vent terminal for
sooting or obstruction and correct if present.
 Vacuum and clean any excess debris in the
fi rebox that is not supposed to be there.
 Test and measure the fl ame failure response
time of the fl ame safety system. It must de-
energize the safety shutoff in no more than
30 seconds.
 Check all accessible gas-carrying tubes, con-
nections, pipes and other components for
leaks. See Set up Gas Supply section of the
fi replace Installation Manual.