3-3.
Heat Sink (GP) Assembly
Preparation
1.
Remove the cabinet (G) assembly. (Refer to
Procedure
1.
Disconnect the harness from the connector (CN4651) on the GR-1003 board.
2.
Disconnect the coaxial cable from the connector (J7391) on the WF-1008 board.
3.
Release the coaxial cable from the groove and rib of the inner mold (G).
4.
Remove the two screws.
HXR-NX80/HXR-MC88
"3-2. Cabinet (G)
GR-1003 board
CN4651
WF-1008 board
J7391
Assembly".)
Harness
Precision screws
(P1.7 x 4)
Inner mold (G)
Groove
Coaxial cable
Rib
3-4