Self-diagnosis Code
Block
Detailed
Function
Code
E
6 1
3 0
E
6 1
3 1
E
6 1
*1
4 0
E
6 1
*1
4 1
E
6 1
4 2
*1
E
6 1
*1
4 3
E
6 1
4 4
*1
E
6 2
0 0
E
6 2
0 1
E
6 2
0 2
E
6 2
0 3
E
6 2
0 4
E
6 2
1 0
E
6 2
1 1
*1:
Function of this code is not provided in this unit.
*2:
When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items. After
the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
HXR-NX80/HXR-MC88
Symptom/State
Reset position detection error on the
stepper iris initializing
Error in detection of the Reset Posi-
tion at the time of Stepper IR Filter
initialization
CMR initialization error
Connection error between CMR
control IC and CPU.
Error of thermistor (CMR)
Abnormality of steadyshot IC
(CMR)
Position detection error of the CMR
filter.
Steadyshot does not work well.
(With PITCH angular velocity sen-
sor output stopped)
Steadyshot does not work well.
(With YAW angular velocity sensor
output stopped)
Abnormality of IC for steadyshot.
Communication error of steadyshot
IC and CPU
Image vibration correction during
steadyshot does not work.
Shift lens initializing failure
Shift lens overheating (PITCH)
Correction
Turn the power on to open lens barrier. Disconnect the bat-
tery or power cord, and then connect again. And confirm
that the iris blades in lens are working.
If iris blades do not work, check the iris motor drive circuit
in lens drive block. If iris blades work normally, confirm
that they are closing completely and confirm following
items.
Case of the iris blades do not close normally. Replace
the lens block.
Case of "E: 61: 30" is appeared and iris blades closed
completely. Confirm that communication with lens
block is normal.
Case of LCD is not displayed normally, check that
connection between imager board and main board.
Case of LCD is displayed normally, replace the lens
block.
Check the signal line connection between the lens block and
the lens control circuit.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
Turn power off and turn power on again.
Turn power off and turn power on again.
Turn power off and turn power on again.
Turn power off and turn power on again.
Turn power off and turn power on again.
The peripheral circuit of the PITCH angular velocity sensor
may be faulty.
Replace the board that contains this peripheral circuit.
The peripheral circuit of the YAW angular velocity sensor
may be faulty.
Replace the board that contains this peripheral circuit.
Check signal line connections from CPU through steady-
shot IC to PITCH/YAW drive.
When there is no problem with the connections, replace the
board that contains this peripheral circuit.
The steadyshot circuit may be faulty.
Replace the board that contains this peripheral circuit.
The image vibration angular velocity sensor (ROLL SEN-
SOR) peripheral circuit may be faulty.
Replace the board that contains this peripheral circuit.
*2
Replacement of lens block.
If an error occurs again, steadyshot circuit may be faulty.
Replace the board that contains this peripheral circuit.
Check signal line connections from CPU through steady-
shot IC to PITCH/YAW drive.
When there is no problem with the connections, check
whether this error is due to the lens or the board. Replace
the faulty lens or board.