Owner’s Manual MODEL CMA-180VL/180VL Tall Installation and Operation Manual Rev 2.01B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E...
HEIGHT (216-219)cm 34” STANDARD TABLE HEIGHT (86.3cm) 17 ½” MAX CLEARANCE FOR DISHES (44cm) 6” (15.2”) MINIMUM CLEARANCE FOR FAN 12” (30.4”) RECOMMENDED 11 ½“ – 12½“ DRAIN CONNECTION (OFF FLOOR) (29-32cm) Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.01B...
Page 4
65 PSIG are present, a pressure regulating valve must be installed in the water line to the dishwasher (by others). If flowing pressure is lower than 15 psi, improper machine operation may result. Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.01B...
2.1. Introduction to CMA-180VL The CMA-180VL is a hot water sanitizing, single rack, door-type dishmachine. It is a stand-alone machine featuring a self-contained booster heater. The only external connections necessary are power supply, water supplies, drainpipe, and chemical dispensers. The machine utilizes re- circulated wash water and fresh water final rinse.
The flush-down or cleaning of the condenser is only done at the end of day and sometimes after each service when the main power switch is turned to the off position. Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.01B...
Account’s drain should be no higher than 11” to allow the machine to drain properly. Electrical and plumbing connections must be made by qualified person who comply with all available Federal, State, and Local Health, Electrical, Plumbing and Safety codes Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.01B...
Electrical and plumbing connections must be made by qualified person who comply with all available Federal, State, and Local Health, Electrical, Plumbing and Safety codes Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.01B...
(see red line on the photo) and then mount it on the tray track using the same bolts, washers and lock nuts used for straight application. Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.01B...
20 PSI. NOTE: Booster heater is filled during this procedure. 5. Connect the detergent and rinse dispenser to the power block supplied & labeled inside the control panel (208-220) volt. Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.01B...
Page 12
41-Second steam evacuation cycle. Once the full cycle is finished, the door safety interlock arm will be retracted thus allowing the doors to wash cabinet to be opened. Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.01B...
2.2.8. Electrical Requirements The CMA-180VL comes standard factory, wired for 3-phase operation. Check the electrical data plate to confirm this. Refer to “Electrical Requirements” Figure 1-A, for proper wiring instruction for both rectangular booster and wash heaters conversion. Also check the wiring diagram to properly wire the terminal power block, tank heater, and booster heater for 1 phase (or 1B diagram below).
WARNING: Insure that the machine is properly grounded and complies with all local and national codes. Injury or death may occur from shock, if the machine is not properly grounded. Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.01B...
Page 15
Install power supply wires, L1, L2 and L3 (3-Phase) to the appropriate terminals marked L1, L2, and L3 on the power block. (If applicable, the high or “wild” leg must be connected to the L2 Terminal.) Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.01B...
Ventless features not working Replace if faulty, properly Check exhaust fan. Assure minimum clearance for is 6” Check cam timer setting Change the setting Faulty # 6 micro switch in cam timer Replace micro switch. Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.01B...
Immersion Heater 6 Kw 3hp/1ph, 240V 17523.51 Hi Limit Switch 250 deg NOTE: CMA recommend that this Model CMA-180VL initial parts kit be kept on hand, as a back up supply, in the event your machine should require emergency service.
Pre-selected delay period can be adjusted by turning dip switches on for proper time setting. Removal of input power will reset the control. AUTO-FILL SWITCH violet violet WATER SOLENOID VALVE orange blue blue Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.01B...