Summary of Contents for CMA Dishmachines CMA-180VL
Page 1
Owner’s Manual Keep with machine for reference MODEL CMA-180VL Installation and Operation Manual Rev 2.00A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E...
2. Getting Started 2.1. Introduction to CMA-180VL 2.1.1. Plumbing Chart Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
Page 6
(41F -65F) before entering the booster heater. Operation of the CMA-180VL is automatic. When the door is opened and then closed, the wash cycle begins automatically. To initially fill the machine daily, press auto fill rocker switch. The machine is full when water begins to flow into the scrap trap.
The conduit needs to be of sufficient length and Electrical and plumbing connections must be made by qualified person who comply with all available Federal, State, and Local Health, Electrical, Plumbing and Safety codes Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
Page 8
(supplied with your dispenser). 3. A 7/8” detergent injection hole is provided in the back of the wash tank. Remove the S.S. plug and install the detergent fitting (supplied with your dispenser). Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
Page 9
The reference manual supplied with the dispenser shows you how to program it. Keep in mind while reading the reference manual that the CMA-180VL operates in “probe” mode. (This mode is selected by setting a value of “1” in screen 21).
7. A 7/8” chemical probe hole is provided in the wash tank behind wash tank heater cover. 8. A 7/8” detergent fitting hole is provided in the wash tank behind the machine. 9. Check the machine operating temperatures. Adjust if necessary. Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
Page 12
When water is observed entering the wash tank this indicates the booster tank is full and removed wire can be connected. Failure to follow these important instructions will destroy the heating element because of dry -firing. Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
Refer to Figure 1-B, for proper wiring instruction for both triangular booster and wash heaters conversion. SINGLE PHASE POWER NOTE: 80amp service is required when CMA-180VL is wired for single-phase with the booster heater. See “Wiring options” section for DUAL 1-phase power supply.
Install power supply wires, L1, L2 and L3 (3-Phase) to the appropriate terminals marked L1, L2, and L3 on the power block. (If applicable, the high or “wild” leg must be connected to the L2 Terminal.) Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
Replace micro switch, Machine does not operate when the door is closed Check cam timer motor Replace timer if needed, Check ice cube relay Replace if faulty, Replace contactor, Faulty wash pump contactor Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
Immersion Heater 6 Kw 3hp/1ph, 240V 17523.51 Hi Limit Switch 250 deg NOTE: CMA recommend that this Model CMA-180VL initial parts kit be kept on hand, as a back up supply, in the event your machine should require emergency service.
Pre-selected delay period can be adjusted by turning dip switches on for proper time setting. Removal of input power will reset the control. AUTO-FILL SWITCH violet violet WATER SOLENOID VALVE orange blue blue Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
Need help?
Do you have a question about the CMA-180VL and is the answer not in the manual?