CMA Dishmachines CMA-180VL Owner's Manual

CMA Dishmachines CMA-180VL Owner's Manual

Hide thumbs Also See for CMA-180VL:

Advertisement

Owner's Manual
Keep with machine for reference
MODEL CMA-180VL
Installation and Operation
Manual
Rev 2.00A
C M A D I S H M A C H I N E S
1 2 7 0 0 K N O T T A V E N U E
GARDEN GROVE, CALIFORNIA 92841
8 0 0 - 8 5 4 - 6 4 1 7
F A X 7 1 4 - 8 9 5 - 2 1 4 1
www.cmadishmachines.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CMA-180VL and is the answer not in the manual?

Questions and answers

Summary of Contents for CMA Dishmachines CMA-180VL

  • Page 1 Owner’s Manual Keep with machine for reference MODEL CMA-180VL Installation and Operation Manual Rev 2.00A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E...
  • Page 2: Table Of Contents

    INITIAL PARTS KIT P/N 1100.17 ..............17 AUTO-FILL SOLID STATE TIMER ..............18 WIRE DIAGRAM CMA-180VL 240V ............... 19 WIRE DIAGRAM CMA-180VL 240V BOOSTER ONLY ......20 WIRE DIAGRAM CMA-180VL 480V ............... 21 WIRE DIAGRAM CMA-180VL 480V BOOSTER ONLY ......22 Page MODEL CMA-180VL INSTALLATION &...
  • Page 3: Specifications

    29” (76.7cm) WIDTH 25 ½” (65cm) HEIGHT 85 ¼”-86 ¼” (216-219)cm STANDARD TABLE HEIGHT 34” (86.3cm) MAX CLEARANCE FOR DISHES 17 ½” (44cm) DRAIN CONNECTION (OFF FLOOR) 11 ½“ – 12½“ (29-32cm) Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
  • Page 4 VOLTS PHASE AMPS ELECTRICAL RATING 332# SHIPPING WEIGHT Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
  • Page 5: Getting Started

    2. Getting Started 2.1. Introduction to CMA-180VL 2.1.1. Plumbing Chart Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
  • Page 6 (41F -65F) before entering the booster heater. Operation of the CMA-180VL is automatic. When the door is opened and then closed, the wash cycle begins automatically. To initially fill the machine daily, press auto fill rocker switch. The machine is full when water begins to flow into the scrap trap.
  • Page 7: Receiving And Installation

    The conduit needs to be of sufficient length and Electrical and plumbing connections must be made by qualified person who comply with all available Federal, State, and Local Health, Electrical, Plumbing and Safety codes Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
  • Page 8 (supplied with your dispenser). 3. A 7/8” detergent injection hole is provided in the back of the wash tank. Remove the S.S. plug and install the detergent fitting (supplied with your dispenser). Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
  • Page 9 The reference manual supplied with the dispenser shows you how to program it.  Keep in mind while reading the reference manual that the CMA-180VL operates in “probe” mode. (This mode is selected by setting a value of “1” in screen 21).
  • Page 10: Water Tempering Kit (Optional)

    2.2.5. Water Tempering Kit (Optional) Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
  • Page 11: Installation Checklist

    7. A 7/8” chemical probe hole is provided in the wash tank behind wash tank heater cover. 8. A 7/8” detergent fitting hole is provided in the wash tank behind the machine. 9. Check the machine operating temperatures. Adjust if necessary. Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
  • Page 12 When water is observed entering the wash tank this indicates the booster tank is full and removed wire can be connected. Failure to follow these important instructions will destroy the heating element because of dry -firing. Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
  • Page 13: Electrical Requirements

    Refer to Figure 1-B, for proper wiring instruction for both triangular booster and wash heaters conversion. SINGLE PHASE POWER NOTE: 80amp service is required when CMA-180VL is wired for single-phase with the booster heater. See “Wiring options” section for DUAL 1-phase power supply.
  • Page 14: Wiring Options

    Install power supply wires, L1, L2 and L3 (3-Phase) to the appropriate terminals marked L1, L2, and L3 on the power block. (If applicable, the high or “wild” leg must be connected to the L2 Terminal.) Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
  • Page 15: Quick Service Guide

    Replace micro switch, Machine does not operate when the door is closed Check cam timer motor Replace timer if needed, Check ice cube relay Replace if faulty, Replace contactor, Faulty wash pump contactor Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
  • Page 16: Initial Parts Kit P/N 1100.17

    Immersion Heater 6 Kw 3hp/1ph, 240V 17523.51 Hi Limit Switch 250 deg NOTE: CMA recommend that this Model CMA-180VL initial parts kit be kept on hand, as a back up supply, in the event your machine should require emergency service.
  • Page 17: Auto-Fill Solid State Timer

    Pre-selected delay period can be adjusted by turning dip switches on for proper time setting. Removal of input power will reset the control. AUTO-FILL SWITCH violet violet WATER SOLENOID VALVE orange blue blue Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
  • Page 18: Wire Diagram Cma-180Vl 240V

    7. Wire Diagram CMA-180VL 240V CONTACTOR CONTACTOR CONTACTOR HEATER PUMP WASH HEATER BOOSTER Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
  • Page 19: Wire Diagram Cma-180Vl 240V Booster Only

    8. Wire Diagram CMA-180VL 240V Booster Only Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
  • Page 20: Wire Diagram Cma-180Vl 480V

    9. Wire Diagram CMA-180VL 480V * AMP FUSE SLOW BLOW (x2) 1.25 AMP FUSE SLOW BLOW (x2) Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...
  • Page 21: Wire Diagram Cma-180Vl 480V Booster Only

    10. Wire Diagram CMA-180VL 480V Booster Only Page MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00...

Table of Contents