WARNING:
When battery is very low, do not continue to operate the machine. Battery
damage may result.
6.
When the solution tank runs empty,
raise the brush head off the floor.
Keep the squeegee down and continue
to vacuum until all the dirty water is
picked up.
NOTE:
See TANK DRAINING section to learn how to drain recovery and solution
tanks.
The machine is equipped with a resettable circuit breaker (see machine components, item #22) to protect the
Main controller. If the circuit breaker should trip, it can't be reset immediately. You must first determine what
caused the breaker to trip, and allow the controller to cool down and then you can manually reset the circuit
breakers. (See Fig. 18)
NOTE:
Contact a Authorized Service center for machine repairs.
The Timer (see Panel components, item #12 (#10 if you got a machine with the new panel)) records the num-
ber of total hours the brush motor has been powered on. Use the hour meter to determine when to perform
recommended maintenance procedures and to record service history.