The only electrical input connections to the dryer are the
3-phase (3ø) power leads (L1, L2, L3, and sometimes
neutral) and ground. Single-phase (1ø) power for the control
circuit and for any single-phase (1ø) motors (if present) is
done internally to the dryer by the factory at the oven contactor.
No single-phase (1ø) input connection is required on a
3-phase (3ø) dryer.
The neutral will only be used on 4-wire service. This is
typical for 380-416V, 50 Hz.
CAUTION: The dryer must be grounded. A ground lug
has been provided for this purpose.
Input connection wiring must be sized properly to handle
the dryer's current draw. This information is printed on the
dryer's data label.
Electric Models Only
Single-Phase (1ø) Wiring Connections / Hookup
3-Phase (3ø) Wiring Connections / Hookup

Gas Information ______________________

It is your responsibility to have all plumbing connections,
materials, and workmanship conform to local and state
regulations or codes of the country of destination. In the
absence of such codes, all plumbing connections,
materials, and workmanship must conform to the applicable
local requirements. In the USA this is the National Fuel Gas
Code ANSI Z223.1-LATEST EDITION, or in Canada, the
Canadian Installation Codes CAN/CGA-B149.1-M91
(Natural Gas) or CAN/CGAB149.2-M91 (Propane Gas) or
LATEST EDITION.
In Australia, the fuel gas code is AS/NZS5601, local authority,
gas, electricity, and any other relevant statutory regulations.
It is important that gas pressure regulators meet applicable
pressure requirements, and that gas meters be rated for
the total amount of all the appliance Btu being supplied.
WFR 112807- 15
IMPORTANT: Failure to comply with these codes or
ordinances, and/or the requirements stipulated in this
manual, can result in personal injury and improper
operation of the dryer.
For ease of service, the individual gas supply line of each
dryer must have its own manual shutoff valve.
Failure to isolate or disconnect the dryer from supply as
noted can cause irreparable damage to the gas valve,
voiding the warranty.
The dryer and its individual shutoff valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psig (3.5 kPa) for non-CE dryers or 50 mb
for CE dryers.
NOTE: The dryer must be isolated from the gas supply
piping system by closing its individual manual shutoff
valve during any pressure test of the gas supply system at
test pressures equal to or less than 1/2 psig (3.5 kPa) for
non-CE dryers or 50 mb for CE dryers.
Fire or explosion could result due to failure of isolating
or disconnecting the gas supply as noted.
NOTE: Undersized gas piping will result in ignition
problems, slow drying, increased use of energy, and can
create a safety hazard.
The dryer must be connected to the type of heat/gas indicated
on the data label and pressure must be confirmed. If this
information does not agree with the type of gas available,
do not operate the dryer. Contact the reseller who sold the
dryer or contact the manufacturer.
The input ratings shown on the data label are for elevations
up to 2,000 feet (610 meters), unless elevation requirements
of over 2,000 feet (610 meters) were specified at the time
the dryer order was placed with the factory. The adjustment
or conversion of dryers in the field for elevations over 2,000
feet (610 meters) is made by changing each burner orifice.
If this conversion is necessary, contact the reseller who sold
the dryer or contact the manufacturer.
IMPORTANT: If connection to this appliance is made with
a flexible hose, it must be suitable for the appliance
category in accordance with national installation
regulations of the country of destination, and if in doubt
the installer must contact the supplier. The manufacturer
of this appliance does not recommend the use of flexible
gas supply line/hose. An external gas supply shutoff must
be provided.
CE and Australian Dryers
There are 2 N.P.T. to B.S.P.T. adaptors included with each
dryer, which must be installed to the gas inlets. The adaptors
are shipped in the upper tumbler.
IMPORTANT: Pipe joint compounds that resist the action
of natural, propane, and butane gases must be used.
www.adclaundry.com