Electrical Information ________________

Electrical Requirements
All electrical connections must be made by a properly
licensed and competent electrician. This is to ensure that
the electrical installation is adequate and conforms to local,
state, and national regulations or codes of the country of
destination. In the absence of such codes, all electrical
connections, materials, and workmanship must conform to
the applicable requirements of the National Electrical Code
ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the
Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or
LATEST EDITION.
IMPORTANT: Failure to comply with these codes or
ordinances, and/or the requirements stipulated in this
manual can result in personal injury or component failure.
NOTE: Component failure due to improper installation will
void the warranty.
Each pocket should be connected to an independently
protected branch circuit. The dryer must be connected with
copper wire only. Do not use aluminum wire, which could
cause a fire hazard. The copper conductor wire/cable must
be of proper ampacity and insulation in accordance with
electric codes for making all service connections.
NOTE: The use of aluminum wire will void the warranty.
An individual ground circuit must be provided to each
pocket, do not daisy chain.
Component failure due to improper voltage application
will void the warranty.
The manufacturer reserves the right to make changes in
specifications at any time without notice or obligation.
IMPORTANT: A separate protected circuit must be
provided to each pocket.
It is necessary to have a power disconnect for each
pocket. These disconnects must be located within 9
meters of the unit and also be identified as being one of
two power sources supplying a dryer.
The dryer must be connected to the electric supply shown
on the data label. In the case of 208 VAC or 230/240
VAC, the supply voltage must match the electric service
specifications of the data label exactly.
The wire size must be properly sized to handle the related
current.
WARNING
!
208 VAC and 230/240 VAC are not the same. Any
damage done to dryer components due to improper
voltage connections will automatically void the
warranty.
WFR 112807- 15
WARNING
!
Dryers built for use with a voltage between 200 and
230/240 must verify the input voltage during
installation. If the nominal voltage is outside of the
medium tolerances shown on the diagram below,
adjust the autotransformers, located near the burner
assemblies. To adjust the autotransformer wiring,
place the red wire on the appropriate tap (HIGH, MED,
LOW) of the autotransformer. For additional wiring
details, refer to the electrical diagram located on the
inside of the control panel.
Electrical Service Specifications
Gas Models Only
ELECTRICAL SERVICE SPECIFICATIONS (PER POCKET)
IMPORTANT:
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
NOTES:
A.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY . Calculate/determine correct fuse
value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
B.
Circuit breakers are thermal-magnetic (industrial) motor curve type
ONLY . For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.
C.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
120
200
208
220
230
240
www.adclaundry.com
(Gas Models Only)
LINE VOLTAGE
TERM
50 Hz
60 Hz
260
283
HIGH
226
249
239
260
MED
208
230
217
236
LOW
189
208
APPROX.
WIRE
AMP DRAW
PHASE
SERVICE
60 Hz
2
10.3
2
8.7
2
8.4
2
8.1
2
2
7.7
CIRCUIT
BREAKER
50 Hz
15
8.8
15
15
8.1
15
7.4
15
7.0
15