Preparation for Operation / Start-Up__

The following items should be checked before attempting
to operate the dryer:
• Read all "CAUTION," "WARNING," and "DIRECTION"
labels attached to the dryer.
• Check incoming supply voltage to be sure that it is the
same as indicated on the data label. In the case of 208
VAC or 230/240 VAC, the supply voltage must match the
electric service exactly.
• GAS MODELS – Check to ensure that the dryer is
connected to the type of heat/gas indicated on the dryer
data label.
• GAS MODELS – Be sure that all gas shutoff valves are
in the open position.
• Be sure all back panels (guards) and electric box
covers are in place.
• Be sure the service doors are closed and securely in
place.
• Be sure the lint door/drawer is securely in place.
• Rotate the tumbler (drum) by hand to be sure it moves
freely.
• Check bolts, nuts, screws, terminals, and fittings for
tightness and security.
• Check that the vent is connected to the dryer and is
exhausted to the outdoors.
• STEAM MODELS – Check to ensure all steam shutoff
valves are open.

Preoperational Test __________________

All dryers are thoroughly tested and inspected before leaving
the factory. However, a preoperational test should be
performed before the dryer is publicly used. It is possible
that adjustments have changed in transit or due to marginal
location (installation) conditions. Installer must instruct the
user on how to correctly operate the dryer before leaving.
Turn on electric power to the dryer.
Refer to the Operating Instructions for starting your particular
model dryer.
Gas Dryers
Open all shutoff valves.
WFR 112807- 15
When a gas dryer is first started (during initial start-up), it
has a tendency not to ignite on the first ignition attempt.
This is because the gas supply piping is filled with air, so it
may take a few minutes for the air to be purged from the
lines.
NOTE: During the purging period, check to be sure that
all gas shutoff valves are open.
A gas pressure test should be taken at the gas valve
pressure tap of each dryer to ensure that the water column
pressure is correct and consistent.
NOTE: Water column pressure requirements (measured
at the pressure tap of the gas valve body) must be
verified.
IMPORTANT: In most cases there is no regulator provided
in a propane dryer. The water column pressure must be
regulated at the source (propane tank), or an external
regulator must be added to each dryer.
Electrical Dryers
Check to ensure that electric oven/contactor assembly is
activating.
Safety Related Circuits
Make a complete operational check of all safety related
circuits:
• Door Switch(es)
• Hi-Limit Thermostats
• Sail Switch
Make a complete operational check of all operating controls.
Tumbler Coating
The tumbler is treated with a protective coating. We suggest
dampening old garments or cloth material with a solution
of water and nonflammable mild detergent and tumbling
them in the tumbler to remove this coating.
Microprocessor Programs / Selections
Each microprocessor controller (computer) has been
preprogrammed by the factory with the most commonly used
parameter (program) selections. If computer program
changes are required, refer to the computer programming
manual, which was shipped with the dryer.

Preoperational Instructions __________

IMPORTANT: For more detailed information regarding the
microprocessor controller (computer), refer to the
microprocessor user's manual included with the dryer.
Coin Models
Microprocessor Controller (Computer)
When the microprocessor controller (computer) is in the
ready state, the L.C.D. screen will display "Ready, Insert
$XX.XX (amount) to Start".
Insert coin(s). Once the correct "Amount to Start" has been
inserted, the L.C.D. will display "Select Temperature".