ML-82 (Gas - DSI /Steam Models) Installation Manual American Dryer Corporation 041700WM/tcosta ADC Part No. 113143...
Page 2
The following FOR YOUR SAFETY caution must be posted near the dryer in a prominent location. We have tried to make this manual as complete as possible and hope you will find it useful. ADC reserves the right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material, and to change or discontinue models.
Page 19
should not exceed must be must be DO NOT...
Page 20
THE DUCT SIZE MUST NOT BE REDUCED ANYWHERE DOWN STREAM OF THE DRYER should not exceed...
Page 21
should be must be must be DO NOT should be...
Page 22
should be should not exceed must be must be DO NOT...
Page 24
DO NOT use aluminum wire which could cause a fire hazard. must be...
Page 25
M LG-82 (Gas) M LS-82 (Steam) LECTRIC ERVICE PECIFICATIONS PER DRYER IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage. NOTE: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY. B.
YPE OF Natural Liquid Propane 8.7 mb 26.1 mb Manifold Pressure* 3.5 inches W.C. 10.5 inches W.C. 14.92 - 29.9 mb 26.1 mb Inline Pressure 6.0 - 12.0 inches W.C. 10.5 inches W.C. Shaded areas are stated in metric equivalents * Measured at gas valve pressure tap when the gas valve is on.
Page 31
must be must be Operating Steam Pressure Maximum 125 psig 861.84 kPa Minimum 100 psig* 689.47 kPa Heat Input (Normal Load) 7 Bhp Consumption (Approximate) 239 lbs/hr 108.41 kg/hr Shaded areas are stated in metric equivalents * Minimum operating pressure for optimum results.
Compressed Air Supply Air Pressure Normal 80 PSI 5.51 bars Minimum Supply 70 PSI 4.82 bars Maximum Supply 90 PSI 6.20 bars Shaded areas are stated in metric equivalents...
Page 35
THE SUPPLY VOLTAGE MUST MATCH THE ELECTRIC SERVICE EXACTLY...
FOR PHASE 6 MODELS (GAS MODELS ONLY) IMPORTANT This dryer is equipped with a burner hi- limit and tumbler/lint chamber hi-limit ther- mostat which must be reset manually. WARNING: Discontinue power to dryer before attempting to reset hi-limit. ADC P/N: 114093...
Page 52
MANUAL RESET HI-LIMIT INSTRUCTIONS FOR PHASE 6 MODELS (STEAM MODELS ONLY) IMPORTANT This dryer is equipped with a lint chamber hi-limit thermostat which must be reset manually. WARNING: Discontinue power to dryer before attempting to reset hi-limit. ADC P/N: 114501...