Gas Information _______________________

It is your responsibility to have all plumbing connections,
materials, and workmanship conform to local and state
regulations or codes of the country of destination. In the
absence of such codes, all plumbing connections, materials,
and workmanship must conform to the applicable local
requirements. In the USA this is the National Fuel Gas Code
ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian
Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or
CAN/CGAB149.2-M91 (L.P. Gas) or LATEST EDITION.
In Australia, the fuel gas code is AS/NZS5601, local authority,
gas, electricity, and any other relevant statutory regulations.
It is important that gas pressure regulators meet applicable
pressure requirements, and that gas meters be rated for the
total amount of all the appliance Btu being supplied.
IMPORTANT: Failure to comply with these codes or
ordinances, and/or the requirements stipulated in this
manual, can result in personal injury and improper
operation of the dryer.
For ease of service, the individual gas supply line of each
dryer must have its own manual shutoff valve.
Failure to isolate or disconnect the dryer from supply as
noted can cause irreparable damage to the gas valve,
voiding the warranty.
The dryer and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess
of 1/2 psig (3.5 kPa) for non-CE dryers or 50 mb for CE
dryers.
NOTE: The dryer must be isolated from the gas supply
piping system by closing its individual manual shutoff valve
during any pressure test of the gas supply system at test
pressures equal to or less than 1/2 psig (3.5 kPa) for non-
CE dryers or 50 mb for CE dryers.
Warning
!
Fire or explosion could result due to failure of
isolating or disconnecting the gas supply as
noted.
Heat Input / Gas Consumption / Orifice (Injector) Data
(For Non-CE [European] and Non-AGA [Australia] Models Only)
Gas Specifications for Non-CE and Non-AGA Approved Dryers***
Gas Type and
Nominal Heating Value
Natural
*Liquid Propane
Shaded areas are stated in metric equivalents
*
Gas valve's internal regulator disabled.
** Information is per pocket/tumbler.
*** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
112809 - 6
Supply
Pressure
B tu /ft
in WC
Btu/hr
3
1,000
7.0-13.0
52,500
2,500
11.0
52,500
www.adclaundry.com
NOTE: Undersized gas piping will result in ignition
problems, slow drying, increased use of energy, and can
create a safety hazard.
The dryer must be connected to the type of heat/gas indicated
on the data label and pressure must be confirmed. If this
information does not agree with the type of gas available, do
not operate the dryer. Contact the reseller who sold the dryer
or contact the manufacturer.
The input ratings shown on the data label are for elevations
up to 2,000 feet (610 meters), unless elevation requirements
of over 2,000 feet (610 meters) were specified at the time the
dryer order was placed with the factory. The adjustment or
conversion of dryers in the field for elevations over 2,000 feet
(610 meters) is made by changing each burner orifice. If this
conversion is necessary, contact the reseller who sold the
dryer or contact the manufacturer.
IMPORTANT: If connection to this appliance is made with a
flexible hose, it must be suitable for the appliance category
in accordance with national installation regulations of the
country of destination, and if in doubt the installer must
contact the supplier. The manufacturer of this appliance
does not recommend the use of flexible gas supply line/
hose. An external gas supply shutoff must be provided.
CE and Australian Dryers
There are 2 N.P.T. to B.S.P.T. adaptors included with each
dryer, which must be installed to the gas inlets. The adaptors
are shipped in the upper tumbler.
IMPORTANT: Pipe joint compounds that resist the action of
natural, propane, and butane gases must be used.
Warning (CE Dryers Only)
!
This appliance must only be operated with the
gas type indicated on the dryer's data plate. If
the appliance is converted (gas type changed), a data
plate amendment must be obtained from American Dryer
Corporation for CE approved units.
Gas Connections
Inlet connection ..... 1/2" N.P.T.
Inlet supply size .... 1/2" Diameter Pipe (minimum)
**Gross
Orifice Size
Heat Input
kW
DMS
15.37
21
15.37
45
3/8" B.S.P.T. (CE and Australian dryers)
Burner
**Orifice
Pressure
(Injector)
Quantity
mm
in WC
4.038
1
3.0
2.082
1