Advertisement

AD-35i / AD-50i / AD-80i
Installation/Operator Manual
WARNING: For your safety the
! ! ! ! !
information in this manual must be
followed to minimize the risk of fire or
explosion or to prevent property damage,
personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Clear the room, building or area of
all occupants.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
88 Currant Road, Fall River MA 02720-4781 USA / Telephone: +1 (269) 923-3000 / Fax: +1 (508) 678-9447
M-50p / M-80p
American Dryer Corporation
e-mail: mdl-service@whirlpool.com / www.adclaundry.com
AVERTISSEMENT: Assurez-vous
! ! ! ! !
de bien suivre les instructions
données dans cette notice pour réduire
au minimum le risqué d'incendie ou
d'explosion ou pour éviter tout dommage
matériel, toute blessure ou la mort.
—Ne pas entreposer ni utiliser d'essence
ni d'autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.
—QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
Ne pas tenter d'allumer d'appareils.
Ne touchez à aucun interrupteur. Ne
pas vous server des téléphones se
trouvant dans la bâtiment.
Évacuez la pièce, le bâtiment ou la
zone.
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.
—L'installation et l'entretien doivent être
assurés par un installateur ou un
service d'entretien qualifié ou par le
fournisseur de gaz.
WFR113539-13

Advertisement

Table of Contents
loading

Summary of Contents for ADC AD-35i

  • Page 1 AD-35i / AD-50i / AD-80i M-50p / M-80p Installation/Operator Manual AVERTISSEMENT: Assurez-vous WARNING: For your safety the ! ! ! ! ! ! ! ! ! ! de bien suivre les instructions information in this manual must be données dans cette notice pour réduire followed to minimize the risk of fire or au minimum le risqué...
  • Page 2 Replacement parts can be obtained from your reseller or the ADC factory. When ordering replacement parts from the factory, you can FAX your order to ADC at +1 (508) 678-9447 or telephone your order directly to the ADC Parts Department at +1 (269) 923-3000. Please specify the dryer model number and serial number in addition to the description and part number, so that your order is processed accurately and promptly.
  • Page 3: Table Of Contents

    Safety Precautions ............4 covers or guards are removed from the machine to allow access for cleaning, adjusting, installation, or AD-35i Specifications ........... 6 testing of any equipment per OSHA standards. AD-50i / M-50p Specifications ........8 Please observe all safety precautions displayed on the AD-80i / M-80p Specifications ........
  • Page 4: Safety Precautions

    Safety Precautions ____________________ The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produce damage to WARNING the machine and harmful fumes. A program should be established for the inspection and For your safety, the information in this manual must cleaning of lint in the burner area, exhaust ductwork, and area be followed to minimize the risk of fire or explosion around the back of the dryer.
  • Page 5 Fabric softeners or similar products should not be used in a tumbler dryer to eliminate the effects of static electricity unless this practice is specifically recommended by the manufacturer NOTES ______________________________________________________ of the fabric softener or product. WARNING _____________________________________________________________ _____________________________________________________________ To reduce the risk of personal injury, install lockable doors to prevent public access to the rear of the dryers.
  • Page 6: Ad-35I Specifications

    AD-35i Specifications _____________________________________________________________ MAXIMUM CAPACITY (DRY WEIGHT) 35 lb 15.87 kg TUMBLER DIAMETER 30” 76.2 cm 74.61 cm TUMBLER DEPTH 29-3/8” 339.80 L TUMBLER VOLUME 12.0 cu ft 0.74 kW TUMBLER / DRIVE MOTOR 1 hp 0.37 kW BLOWER / FAN MOTOR 1/2 hp 80.96 cm...
  • Page 7 AD-35i Specifications _____________________________________________________________ NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. WFR113539 - 13 www.adclaundry.com...
  • Page 8: Ad-50I / M-50P Specifications

    AD-50i / M-50p Specifications _____________________________________________________ 22.67 kg MAXIMUM CAPACITY (DRY WEIGHT) 50 lb TUMBLER DIAMETER 32-3/4” 83.18 cm TUMBLER DEPTH 37-1/2” 95.25 cm TUMBLER VOLUME 18.3 cu ft 518.19 L TUMBLER / DRIVE MOTOR 1 hp 0.75 kW BLOWER / FAN MOTOR* 3/4 hp 0.56 kW...
  • Page 9 AD-50i / M-50p Specifications _____________________________________________________ NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. WFR113539 - 13 www.adclaundry.com...
  • Page 10: Ad-80I / M-80P Specifications

    AD-80i / M-80p Specifications _____________________________________________________ 36.28 kg MAXIMUM CAPACITY (DRY WEIGHT) 80 lb 93.98 cm TUMBLER DIAMETER 37” 90.01 cm TUMBLER DEPTH 35-7/16” 624.39 L TUMBLER VOLUME 22.05 cu ft 0.74 kW TUMBLER / DRIVE MOTOR 1 hp 0.56 kW BLOWER / FAN MOTOR* 3/4 hp...
  • Page 11 AD-80i / M-80p Specifications _____________________________________________________ NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. WFR113539 - 13 www.adclaundry.com...
  • Page 12: Installation Procedures

    To remove the skid from CGA-B149.2-M91 (Propane Gas) or LATEST EDITION (for the AD-35i, AD-50i/M-50p, or AD-80i/M-80p, locate and remove General Installation and Gas Plumbing) or Canadian Electrical the 2 bolts securing the base of the dryer to the wooden skid.
  • Page 13: Dryer Enclosure Requirements

    NOTE: Component failure due to dry cleaning solvent fumes will void the warranty. A The requirement to allow the lint door to open completely for the AD-35i is 33-inches (83.8 cm), AD-50i/M-50p is 36” A = 12-inches (30.5 cm) (91.4 cm), and AD-80i/M-80p is 40-inches (101.6 cm).
  • Page 14: Exhaust Requirements

    Single Dryer Venting (AD-35i) shall either be retained and subsequently re-evaporated or discharged. IMPORTANT: For the AD-35i, a minimum exhaust duct size of 6-inches (15.24 cm) must be used. CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors.
  • Page 15 Combined Vertical HORIZONTAL SINGLE DRYER VENTING and Horizontal Dryer Venting 8-INCH (20.32 CM) DUCTING For an 8-inch (20.32 cm) combined vertical and horizontal run, the dryer to the outside outlet cannot exceed the sum of dimensions “A” and “B” in the following illustration. This calculation of “A”...
  • Page 16 AD-35i American Dryer Corp. WFR113539 - 13...
  • Page 17 AD-50i/M-50p, AD-80i/M-80p WFR113539 - 13 www.adclaundry.com...
  • Page 18: Electrical Information

    IMPORTANT: Failure to comply with these codes or VOLTAGE SERVICE BREAKER 60 Hz 50 Hz ordinances, and/or the requirements stipulated in this AD-35i manual can result in personal injury or component failure. 1ø 10.2 — 1ø — NOTE: Component failure due to improper installation will 1ø...
  • Page 19 Electric Models Only (AD-35i, AD-50i/M-50p) Electric Models Only (AD-80i/M-80p) ELECTRICAL SERVICE SPECIFICATIONS (PER POCKET) ELECTRICAL SERVICE SPECIFICATIONS (PER POCKET) IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
  • Page 20 IMPORTANT: For personal safety and proper operation, the SINGLE-PHASE ELECTRICAL LEAD CONNECTIONS dryer must be grounded. Black White or Red Provisions are made for ground connection in each dryer at Green the electrical service connection area. Positive Neutral Ground Electrical Connections or L1 or L2 A wiring diagram is located behind the control panel for...
  • Page 21 CAUTION: The dryer must be grounded. A ground Input connection wiring must be sized properly to handle the lug has been provided for this purpose. dryer’s current draw. This information is printed on the dryer’s rating plate. Input connection wiring must be sized properly to handle the IMPORTANT: A strain relief must be used where the input dryer’s current draw.
  • Page 22: Gas Information

    Input connection wiring must be sized properly to handle the dryer’s current draw. This information is printed on the dryer’s rating plate. IMPORTANT: A strain relief must be used where the input wiring enters. Gas Information _______________________ It is your responsibility to have all plumbing connections, materials, and workmanship conform to local and state regulations or codes of the country of destination.
  • Page 23 Heating Value Pressure Pressure Model (Injector) Type Quantity B tu /ft in WC Btu/hr in WC 7.0-13.0 20.5 3.988 Natural 1,000 70,000 AD-35i *Propane 2,500 11.0 70,000 20.5 2.438 10.5 7.0-13.0 36.64 5.22 Natural 1,000 125,000 AD-50i *Propane 2,500 11.0 125,000 36.64...
  • Page 24 12.0 Natural (I 15-30 70,000 20.50 2.386 M 3.988 12.0 2ELL 20.50 1.981 M 3.264 — 1,000 70,000 *Natural (I AD-35i 70,000 20.50 2.386 M 3.264 — 28-30 20.50 1.478 kg/hr 2.261 — *Butane (I 3,175 70,000 *Propane (I 2,500 70,000 20.50...
  • Page 25 (gas type changed), a new installation. rating plate must be obtained from ADC (dryer’s serial number is required to purchase a conversion kit). NOTE: Undersized gas supply piping can create a low or...
  • Page 26 ______ appliance is converted (gas type changed), a new Manifold pressure tested and confirmed to rating plate must be obtained from ADC. be a consistent 10.5 in WC (26.2 mbar): ______ Conversions done improperly can result in a fire or...
  • Page 27: Steam Information

    Installation Instructions The AD-50i/M-50p and the AD-80i/M-80p are available with steam heat. (Steam heat is not available on the AD-35i.) If To ensure an adequate supply of steam is provided, be sure your dryer was manufactured with steam heat, it is your...
  • Page 28 AD-80i/M-80p Steam Piping Schematic (Figure 1) AD-50i/M-50p Steam Piping Schematic (Figure 2) American Dryer Corp. WFR113539 - 13...
  • Page 29: Water Information

    Installation AD-80i/M-80p Water Supply Install an inverted bucket steam trap and check valve at The fire suppression system must be supplied with a minimum least 12-inches (30.48 cm) below each steam coil return water pipe size of 1/2-inch (12.7 mm) and be provided with 40 connection as close to the coil(s) as possible.
  • Page 30: Preparation For Operation / Start-Up

    WARNING NOTE: During the purging period, check to be sure that all gas shutoff valves are open. ELECTRICAL SHOCK HAZARD A gas pressure test should be taken at the gas valve pressure tap of each dryer to ensure that the water column pressure is Electrical shock hazard can result in serious injury.
  • Page 31: Shutdown Instructions

    Warranty tags (Part No. 450064) are available at “no from the factory by calling the Parts Department at +1 (269) charge” from ADC upon request. 923-3000 or you may FAX in your order at +1 (508) 678-9447. The company returning the part(s) must clearly note the...
  • Page 32: Routine Maintenance

    Weekly by the sender. Clean lint accumulation from the lint chamber, thermostat and Shipping charges are not the responsibility of ADC. All returns microprocessor temperature sensor area. The thermostat and should be “prepaid” to the factory. Any “C.O.D.” or “COLLECT”...
  • Page 33: Procedure For Functional Check Of Replacement Components

    Procedure for Functional Check of Replacement Components __________ NOTES ______________________________________________________ DSI Module _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ Theory of Operation: Start the drying cycle. When the gas burner ignites within the chosen trial for ignition time (8-seconds), the flame sensor detects gas burner flame and _____________________________________________________________ signals the DSI module to keep the gas valve open as long as there is a call for heat.
  • Page 34: Rating Plate Information

    CE Plate Standard Plate AGA Label When contacting ADC, the information on the rating plate is required to ensure proper service/parts assistance. The rating plate is located on the upper left side panel of the dryer, behind the control panel.
  • Page 35: Programming

    Programming __________________________ SAIL SWITCH OPEN FAULT – Sail switch remained open after the cycle started. Should have closed. Non-Coin Programming BURNER HIGH LIMIT FAULT – Burner temp. disk has opened. BURNER IGNITION CONTROL – No signal to gas valve from (DSI) module during trial for ignition time. DSI module is bad.
  • Page 36 Phase 7.3.2 Coin Programming Accessing and Clearing Coin Vault Total Enter the programming mode by placing the switch on the Enter program mode by switching program switch (up) while no cycle is in progress. Phase 7 board in the up position while no cycle is in progress.
  • Page 37 NOTES __________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ WFR113539 - 13 www.adclaundry.com...
  • Page 38 WFR113539 13 - 05/15/18...

This manual is also suitable for:

Ad-80iAd-50iM-80pM-50p

Table of Contents