Vega Si-11 Pulse Counter Receives Packets Of The Following Types; Real-Time Clock Adjustment; Packet With Request Of Settings; Packet With Settings - Vega SI-11 User Manual

Pulse counter
Table of Contents

Advertisement

Vega SI-11 / User Manual

VEGA SI-11 PULSE COUNTER RECEIVES PACKETS OF THE FOLLOWING TYPES

1. Real-time clock adjustment

Sent by application on LoRaWAN port 4.
Size in bytes
Field description
1 byte
Packet type, this packet = 255
8 bytes
The value in seconds for which you need to adjust the time.
Can be positive or negative

2. Packet with request of settings

Sent by application on LoRaWAN port 3.
Size in bytes
Field description
1 byte
Packet type, this packet == 1
Answering this packet, the device sends the packet with settings.

3. Packet with settings

Is identical to such packet from device.
Size in bytes
Field description
1 byte
Packet type, this packet == 0
2 bytes
ID of parameter
1 byte
Data length (len)
len bytes
Parameter value
2 bytes
ID of parameter
1 byte
Data length (len)
len bytes
Parameter value
...
...
2 bytes
ID of parameter
1 byte
Data length (len)
len bytes
Parameter value
The package with settings sent to the device may not contain all the settings supported
by the device, but only the part that needs to be changed.
Table of ID of SI-11 parameters and these possible values
ID of
Description
parameter
4
Confirmed uplinks
Revision 26 of 25 August 2021
Data
Possible values
length
1 byte
1 – confirmed
2 – unconfirmed
Data type
uint8
int64
Data type
uint8
Data type
uint8
uint16
uint8
-----
uint16
uint8
-----
...
uint16
uint8
-----
17