Alarm" Packet; Packet With Time Correction Request - Vega SI-11 User Manual

Pulse counter
Table of Contents

Advertisement

Vega SI-11 / User Manual
"Values of basic settings" bit field decoding
Bit
Meaning
0 bit
Activation type: 0 - OTAA, 1 – ABP
1, 2,3 bits
Communication period:
|1 == 0|2==0|3==0| - 5 minutes
|1 == 1|2==0|3==0| - 15 minutes
|1 == 0|2==1|3==0|- 30 minutes
|1 == 1|2==1 |3==0|- 1 hour
|1 == 0|2==0|3==1|- 6 hours
|1 == 1|2==0|3==1|- 12 hours
|1 == 0|2==1|3==1|- 24 hours
4 bits
First input type: 0 – pulse, 1 - security
5 bits
Second input type: 0 – pulse, 1 - security
6 bits
Third input type: 0 – pulse, 1 - security
7 bits
Fourth input type: 0 – pulse, 1 - security
Time zone considered during collection data from an external meter.
2. «Alarm» packet
Sent in case of security input closure on LoRaWAN port 2.
Size in bytes
Field description
1 byte
Packet type, this packet == 2
1 byte
Battery charge, %
1 byte
Values of basic settings (bit field)
1 byte
Input No, where the alarm is detected
4 bytes
Packet time (unixtime UTC)
4 bytes
Input 1 reading (depending on the type – number of pulses or
status: 0 – open, 1 - closed)
4 bytes
Input 2 reading (depending on the type – number of pulses
or status: 0 – open, 1 - closed)
4 bytes
Input 3 reading (depending on the type – number of pulses
or status: 0 – open, 1 - closed)
4 bytes
Input 4 reading (depending on the type – number of pulses
or status: 0 – open, 1 - closed)
When sending alarm packet, the device uses the data taken at moment of alarm triggers.

3. Packet with time correction request

Sent every seven days on LoRaWAN port 4.
Size in bytes
Field description
1 byte
Packet type, this packet == 255
4 bytes
Time of the modem at a moment of the packet transmission
(unixtime UTC)
Revision 26 of 25 August 2021
Data type
uint8
uint8
uint8
uint8
uint32
uint32
uint32
uint32
uint32
Data type
uint8
uint32
15