SPRING AND TRIGGER SPRAY INSTALLATION

FOR ALL UNITS
1.
Fit the flat washer (24) into the top of the
Riser to ensure a water tight seal.
2.
Slide the spring (1) to expose the male
connecting thread (2).
3.
Using the correct spanner, screw the male
thread of the flexible hose into the top
of the riser. Do up firmly but do not over
Support the weight of the
tighten.
hose and spring while tightening to
prevent cross threading and kinking
of the hose.
4.
Slide the spring back over the end of the
hose until it sits on top of the Riser.
Apply Teflon tape or loxeal to the male thread
of the trigger spray.
5.
Screw the Trigger Spray Unit (41) to the
Hose, tighten firmly using a spanner on the
flat section of the Nut.
*Regular service must be carried out on the product to avoid product failure.
www.gentecaustralia.com.au
6.
Tighten using flats on trigger spray and
flats on the Hose
7.
Turn on the Water and test the unit.
Trigger Spray Fixing Methods
Using Teflon Tape
• Apply adequate Teflon tape to the male
thread of the trigger spray.
• Screw hose connection on to trigger
spray then tighten firmly against "O"
Ring Supplied on trigger.
Using Loxeal
• Insert the white teflon washer into the
hose adaptor.
• Apply Loxeal to the male thread of the
trigger spray.
• Screw hose connection on to trigger
spray then tighten firmly against oring.
Test to ensure there are no leaks.