Advertisement

Quick Links

INSTALLATION
MANUAL
GPure Bubblers
90° Bubbler
GPT8000
45° Bubbler
GPT8050
Up Right Bubbler
GPT8050UR

Advertisement

Table of Contents
loading

Summary of Contents for Gentec GPure Bubblers GPT8000

  • Page 1 INSTALLATION MANUAL GPure Bubblers 90° Bubbler GPT8000 45° Bubbler GPT8050 Up Right Bubbler GPT8050UR...
  • Page 2: Table Of Contents

    Contents Product Features Product Range Technical Drawings Unit Components Installation Instructions Maintenance Time Adjustment Instructions Water Flow Adjustment FAQs Product Warranty...
  • Page 3: Product Features

    GPure by Gentec Gentec’s GPure range of lead free bubbler solutions has been developed in response to the call by groups such as enHealth (Environmental Health Standing Committee) for the further reduction of lead in plumbing products that deliver drinking water. enHealth recommends that every effort should be made to reduce exposure to lead in the environment, including lead that may be dissolving into drinking water from some plumbing products.
  • Page 4: Product Range

    Product Range GPT8000 GPT8050 GPURE 90° BUBBLER GPURE 45° BUBBLER GPT8050UR GPURE UPRIGHT BUBBLER ALL IMAGES MAY BE USED FOR SPECIFICATION REFERENCE...
  • Page 5: Technical Drawings

    GPT8000 GPT8050 GPURE 90° BUBBLER GPURE 45° BUBBLER Ø41 Ø41 138.5 100.5 100.5 90° 45° 36.5 36.5 138.5 GPT8050UR GPURE UPRIGHT BUBBLER 100.5 36.5 Ø48 ALL DRAWINGS MAY BE USED FOR SPECIFICATION REFERENCE Ø22 82° Ø26 www.gentecaustralia.com.au...
  • Page 6: Unit Components

    Unit components Description Description Bubbbler Guard Indicator Body Cover Screw Flow Cup Locking Screw Cartridge Flow Adjustment screw Cover Flange Flow regulator Handle Strainer For optimum operational life, the installation of a PRV set to 350kPa is recommended...
  • Page 7: Installation Instructions

    Installation Instructions BUBBLERS GPT8000, GPT8050, GPT8050UR For all Units: Flush water supply pipework prior to installation It is recommended that an isolating stop valve be installed to facilitate ease of maintenance Install the Flow regulator and place the strainer in the inlet connection before screwing the bubbler to the water inlet.
  • Page 8: Maintenance

    Maintenance Important Note For optimum maintenance periodically remove the bubbler from the installation, inspect and clean the strainer. If debris is present in the strainer it is recommended to flush the water supply pipework. O Ring Kit service Service and maintenance must be undertaken by a suitably qualified plumber. Warranty may be void if damage to internal components occurs during this procedure First start by shutting off the main water supply.
  • Page 9 Remove the indicator (1) using a small flat blade screwdriver, then remove the Screw (2) using a 2.5mm allen key. Remove the handle (3), then unscrew the cover flange (4) Remove the cartridge (5) using a shifter Undo the stopper (13) Set aside the crown ring (11) Figure1 Set aside the head valve (8) from the stem...
  • Page 10: Time Adjustment Instructions

    The run time adjustment screw is under the indicator cap. Remove the indicator cap and use a 1.5mm allen key to adjust the timing. Timed Adjustment Range Contact GENTEC before attempting to change • Turning the screw clockwise will reduce flow cups. the run time.
  • Page 11: Water Flow Adjustment

    WATER FLOW ADJUSTMENT This option is suitable for the following references: GPT8000, GPT8050, GPT8050UR To adjust the water flow: Remove the locking screw (9) Using a small flat blade screwdriver adjust the bubbler stream height to the desired position (Refer to schematics below). Replace the locking screw (9) back.
  • Page 12: Faqs

    Notes Scope of Use: GPURE Range Installation is subject to the regulatory requirements of the plumbing code of Australia associated to AS/NZS 3500.1 (Bubblers) and AS/NZS 3500.4 (Taps) Inlet pressure: Maximum 500 kpa Manufacturers recommended pressure: 350 kpa Installation: Refer to manufacturer’s instructions for installation Water quality: In line strainer (supplied) must be installed to ensure water quality Suitable for indoor and outdoor use: GPURE FLOSTOP &...
  • Page 13 Warranty GENTEC PRODUCT QUALITY WARRANTY You have purchased a quality product from GENTEC 2.2.7 include pictures of the alleged defect; in a Australia Pty Ltd ABN 581 552 50285 ). This product reasonable time. is covered by a 10 year replacement warranty which includes 1 year parts and labour.
  • Page 14: Product Warranty

    Law. You are entitled to a replacement or refund 4.3.1 an act, default, omission or representation for a major failure and compensation for any made by some other person, excluding Gentec other reasonably foreseeable loss or damage. or its manufacturer (for example, damage...
  • Page 15 the Principal in relation to specific Goods. 5.3 The address for any notice to be delivered to the Principal is as follows: 4.5 However, nothing in this clause will prevent You from exercising any rights which You may have under the Competition and Consumer Act 2010 or any other law which cannot by law be excluded or modified by agreement.
  • Page 16 www.gentecaustralia.com.au info@gentecaustralia.com.au Unit 6 20-28 Ricketty St, Mascot, Sydney, NSW 2020 P: +612 9319 4422 F: +612 8088 7635...

This manual is also suitable for:

Gpure bubblers gpt8050Gpure bubblers gpt8050ur

Table of Contents