GPure by Gentec Gentec’s GPure range of lead free timed flow tapware has been developed in response to the call by groups such as enHealth (Environmental Health Standing Committee) for the further reduction of lead in plumbing products that deliver drinking water. enHealth recommends that every effort should be made to reduce exposure to lead in the environment, including lead that may be dissolving into drinking water from some plumbing products.
6, 20 -28 Ricketty St www.gentecaustralia.com.au Mascot, NSW 2020 info@gentecaustralia.com.au This drawing is property of LAST UPDATE APPROVED BY All dimensions are in mm Gentec Australia Pty Ltd Steven unless specified. 11/03/20 Penson MAR-LD-GPT01-MB-110320 GPT7000 STAINLESS STEEL TIMED FLOW SINGLE TEMPERATURE WALL MOUNTED BIB TAP.
Unit Components Part No Desctiption Indicator Cap Screw Handle Cartridge Body Flexible Hose Flange (separated in the GPT7000W) www.gentecaustralia.com.au...
Installation Instructions PILLAR TAPS GPT7500 Screw in the fixing bolts and tighten with a screwdriver. From underneath the sink or basin, fix Connect the flexible hose. Care must rubber seal, fixing plate and fixing nuts be taken to not twist the hose so that it use socket set or tube spanner to clamp does not kink during assembly.
Page 7
BIB TAPS GPT7000 For all Units: Flush the water supply pipework prior to installation. Install the flow regulator into the body. Ensure the strainer is installed prior to connection. Place the flange and screw to the water supply. • Note: Ensure that thread sealant does not foul the bubbler inlet, strainer, flow control and timed flow headwork) Select the desired colour indicator and push into the handle.
Operation WATER SUPPLY Where multiple taps may be installed off Min Continuous Flow 50kPa the one service line, ensure that water Working Pressure supply pipe sizing and available pressure Max Continuous Flow 450kPa meets the requirements of the installation Working Pressure and AS/NZS3500 to ensure optimum per- Optimum Flow Working 350Kpa...
Timed Adjustment Range From 1 to 20 Seconds • Turning the screw clockwise will reduce Contact GENTEC before attempting to the run time. change flow cups. Warranty may be void if damage to internal components or spare parts occurs during service / maintenance.
Maintenance Important Note For optimum maintenance periodically remove the tap from the installation, inspect and clean the strainer. If debris is present in the strainer it is recommended to flush the water supply pipework. O Ring Kit service Service and maintenance must be undertaken by a suitably qualified plumber. Warranty may be void if damage to internal components occurs during this procedure.
Page 11
Undo the stopper (12) U Cup Set aside the crown ring (10) Set aside the head valve (7) from the stem Remove the U Cup (8) from the head valve (7) and replace with the new U Cup Remove the U Cup (13) from the stopper (12) and replace it with the new U Cup.
Notes For optimum operational life, the installation of a PRV set to 350kPa is recommended...
Page 13
Warranty GENTEC PRODUCT QUALITY WARRANTY You have purchased a quality product from GENTEC 2.2.7 include pictures of the alleged defect; in a Australia Pty Ltd ABN 581 552 50285 ). This product reasonable time. is covered by a 10 year replacement warranty which includes 1 year parts and labour.
Law. You are entitled to a replacement or refund for a major failure and compensation for any 4.3.1 an act, default, omission or representation made by some other person, excluding Gentec other reasonably foreseeable loss or damage. or its manufacturer (for example, damage...
Page 15
the Principal in relation to specific Goods. 5.3 The address for any notice to be delivered to the Principal is as follows: 4.5 However, nothing in this clause will prevent You from exercising any rights which You may have under the Competition and Consumer Act 2010 or any other law which cannot by law be excluded or modified by agreement.