Electrical Connections; Turning The Machine On & Off; All Models; Remote Control (Optional Accessory) - Jet DC-1100VX-CK1 Operating Instructions And Parts Manual

Table of Contents

Advertisement

Electrical Connections

All electrical connections must
be
electrician. All adjustments or repairs must be
done with the dust collector disconnected from
the power source, unplugged. Failure to comply
may result in serious injury!
The DC-1100VX dust collectors (all models) are rated
at 115/230V, Prewired 115V. Use a plug and outlet
rated at least 20 amps. The circuit for the machine
should also be protected by a minimum 20 amp
circuit breaker or fuse. Keep in mind that a circuit
being used by other machines, tools, lights, heaters,
etc. at the same time will add to the electrical load.
A dedicated circuit to the dust collector will give you
the best results since dust collectors are generally
used at the same time other tools are running.
Turning the Machine On & Off
This machine is intended for
indoor use only.

All Models

Before hooking up to the power source, make sure
that the switch is in the off position.
Turn the dust collector on by pressing the Start
button mounted next to the motor. Press the Stop
button to turn off the dust collector.

Remote Control (Optional Accessory)

The DC-RC RF Remote Power Control unit is
available as an optional accessory (see your dealer
or contact Customer Service by calling the number
on the cover).
Important: The DC-RC Remote Power Control (SN
708636C) can be used for activating Dust Collection
units powered by 115V only up to 1-1/2HP. If your
dust collector is currently set up for 230V operation or
you choose to convert it to 230V at a later time, you
must purchase the DC-RC230 Remote Power
Control unit (SN 708636D).
Figure 13A
done
by
a
qualified
Figure 13B
Dust Collector RF Remote
Power Control (Optional)
The DC-RC Remote Power Control (Figure 14)
should be used for activating Dust Collection units
powered by 115V only up to 1-1/2HP. The DC-RC
Remote Power Control unit is rated at 115V, Single
Phase only. Use an outlet rated at least 20 amps.
The circuit for the device being controlled by the DC-
RC should also be protected by a minimum 20 amp
circuit breaker or fuse.
Before hooking up to the power source, make sure
that the switch is initially in the off position on both
the dust collector and remote control unit (Figure 13).
Turning the DC-RC On & Off
1. Plug the dust collector into the main unit
(Figure 14) and plug the main unit into the power
outlet.
To start a machine or device:
2. Turn the machine itself on.
3. On the main unit place the switch to the ON
position (Figure 13A). The red LED on the main
unit should light up.
4. Press
the
button
transmitter (Figure 14) to turn the machine on.
5. To stop the machine, press the button on the
remote control transmitter again.
When the machine is running, it can be stopped by
placing the switch on the main unit in the off position
(Figure 13B). To restart, repeat steps 3 and 4.
13
This machine is intended for
indoor use only.
on
the
remote
Figure 14
control

Advertisement

Table of Contents
loading