7-10. AIF PUMP

7-11. AIF PC BOARD

Aug. 2008
T his pump keeps the vats filled and is used in the Automatic
Intermittent Filter process.
Replacement:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove the right side panel.
2. Using 1" wrench, loosen both fitting on each side of pump.
3. Using a Phillip's-head screwdriver, remove the 4 screws
securing the bottom of pump.
4. Disconnect the wires in the rear of the pump and pull
assembly from fryer.
5. Pull fittings from faulty pump and attach fittings to the new
pump, in the same orientation.
6. Install new pump assembly in fryer, in reverse order and
then reconnect power to fryer.
This electronic board controls the Automatic Intermittent
Filtering process.
Replacement:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove the left side panel.
2. Using a 3/8" socket or nut driver, remove nuts securing the
cover and remove cover.
3. Pull connectors from PC board.
4. Using a 5/16" socket, remove 6 nuts securing the board
and remove it from the fryer.
5. Install in reverse order. The control connectors are colored-
coded; Left-Red; Middle-White; Right-Blue.