Henny Penny LOV LVG-102 Technical Manual page 29

Split vat & full vat open fryers – gas
Table of Contents

Advertisement

5-2. SPECIAL PROGRAMMING
(Continued)
Feb. 2011
2nd Language (SP-3)
5. Press button and "SP-3 2ND LANGUAGE" scrolls in
left display. Use
FRANCAIS; CAN FREN; ESPANOL; PORTUG;
DEUTSHE; SVENSKA; РУССКИИ or -NONE-.
By setting a second language in the controls, 2 languages
can now be easlily chosen by pressing
during normal operation.
One language shows in left display and a second language
shows in the right display. Pressing the √ button selects the
language in the displays.
Quick Configuration (SP-4)
5. Press button and "SP-4 QUICK CONFIG" shows in
display. Use the
selection in the controls to: CHKN+FISH; FF/HBR; CHKN
or EMPTY.
Polish Duration (SP-5)
6. Press button and "SP-5 POLISH" shows in left
display. Use product buttons
to change polish time, from 5 minutes to a maximum of
10 minutes.
Drain Valve (SP-6)
7. Press button and "SP-6 DRAIN VALVE" scrolls in the
left display. Use the
display to show "NORMAL" or "MANUAL".
NORMAL means drain valves are controlled electronically
and MANUAL means drain valves must be opened by
hand.
Edit Unit Serial Number (SP-7)
8. Press button and "SP-7 S/N √ EDIT" shows in the left
display. Press the right √ button to enter the unit's serial
number in the controls, using the product buttons.
"STD" and "CUST" show in the right displays. Press the √
button under "STD" and the first 2 letters of the serial
number is the standard equipment code, press X button and
a custom equipment code can be entered. THIS SERIAL
NUMBER SHOULD MATCH THE SERIAL NUMBER
ON THE DATA PLATE, ON THE DOOR.
5-4
Model LVG-102, 103, 104
and
buttons to set to: ENGLISH;
and
buttons to change the menu
and
buttons to change the right
button twice