7-6. TEMPERATURE PROBE
REPLACEMENT
(Continued)
Aug. 2008
7. Place nut and new ferrule on the new temperature probe
and insert temperature probe into the compression fitting.
See drawing below.
8. Using the probe gauge in the kit, follow the instructions on
drawing below.
9. Hand-tighten compression nut and then a half turn with
wrench.
Excess force will damage temperature probe.
7-8
Model LVG-102, 103, 104