1. Press and release
the recovery time that oil temperature went from 250°F
(121°C) to 300°F (149°C) shows in the right display. For
example,
REC
30 seconds for the oil temperature to recover to 300°F
(149°C) from 250°F (121°C).
Pressing the
button twice shows the 2nd language, if
programmed.
If no buttons are pressed within 5 seconds in any of stats
modes, the controls revert back to normal operation.
1a. Press and release
reading, date of the last TPM reading, and time stamp of last
TPM reading (only if OQM sensor is installed and enabled).
Cook Cycles Remaining before Filtering
1. Press and release either
shows "COOKS REMAIN" and right display shows the
number of cook cycles before the next auto filter. For
example,
REMA IN
means after 3 more cook cycles on the left vat, the controls
ask operator if they are ready to filter or not. But, 6 more
cook cycles remain on the right vat.
Time and Date
2. Press either
or
shows in the displays.
Filter Pad Usage
3. Press either
or
the present filter has been used is hown in the displays.
Actual Oil Temperature
1. Press
and the actual oil temperature shows in the
display, for each vat.
Set-point Temperature
2. Press
twice and SP shows in the display, along with
the set-point (preset) temperature of each vat.
2-1
Model LVG-102, 103, 104
and REC shows in left display and
means it took 5 minutes and
5:30
, the display will show the last TPM
or
and left display
3
6
twice and time-of-day and date
three times and number of hours