5-5. TECH MODE (Continued)
Feb. 2011
Press
button and "INP E_P_" and "JL_R_DF_" shows in
the displays.
AIF Board Inputs:
E = Stop button
P = Drain Pan
JL = JIB
R = RTI
DF = RTI Discard Tank
Press
button and "OUT F_J_" and "N_DI_JFo" shows in
the displays.
AIF Board Outputs:
Current outputs status from AIF board.
F = Filter Pump.
(F* = Filter pump is on)
J = JIB Pump.
(J* = JIB pump is on)
N = New Oil Pump. (N* = RTI new oil pump on)
DI = Discard Valve. (DIo = RTI disc. valve open/DIc=closed)
JF = JIB Fill Valve. (JFo = RTI JIB fill valve open/
JFc=closed)
Press
button and "REQ F_J_" and "N_DI_JFo_" shows in
the displays.
AIF Board Outputs Requested by the Control Board:
Current outputs status from AIF board.
F = Filter Pump.
(F* = Filter pump is on)
J = JIB Pump.
(J* = JIB pump is on)
N = New Oil Pump. (N* = RTI new oil pump on)
DI = Discard Valve. (DIo = RTI disc. valve open/
DIc=closed))
JF = JIB Fill Valve. (JFo = RTI JIB fill valve open/
JFc=closed)
T-19 - OUTPUTS
F = FAN (PRESSURE SWITCH)- Press
and close the pressure switches
S = SAFETY GAS VALVE (if available) - Press
to open and close the gas safety valves
I = IGNITION MODULE - Press
close the outputs on the ignition modules
H = HEAT OUTPUTS - Press
the heating outputs (ex: gas valve)
5-10
Model LVG-102, 103, 104
E* = E-Stop pressed.
M* = drain pan is missing.
J* = JIB oil level is low.
R* = RTI System Detected
DF* = tank full
or
or
to open and
or
to turn on and off
to open
or