11. Advanced Control Wiring
F1 ‐ fuse (maximum 0.5A) PCB
F2 ‐ fuse (maximum 15A) Over current
J1 ‐ 1&2 MM1 Master gate
J2 ‐ 3&4 SM2 Slave gate
J3 ‐ 5&6 Electric lock, 12VDC, Max current 5A
J3 ‐ 7&8 Flashing light. 12VDC, Max power 21W
J4 ‐ 9 Positive Supply 12V DC
J4 ‐ 10 use with 12 Keypad / Pushbutton for the dual gate operation
J4 ‐ 11 use with 12 Keypad / Pushbutton for the single gate operation
J4 ‐ 12 Logical and Power Ground for external devices
J4 ‐ 13 Positive Supply 12V DC
J4 ‐ 14&15 Photo sensor contacts, must be shorted together if no photocell
J5 ‐ 16 Aerial Antenna cable (Connect to Aerial for increased range)
J6 ‐ Reset Switch
SW2 ‐ This button is used for code learning.
VR1 ‐ Over current limit can be adjusted from min 3.5Amp to Max 7.5Amp
VR2 ‐ Close delay can be adjusted from min 0 second to Max 8 second
22