11. Advanced Control Wiring 
 
 
F1 ‐ fuse (maximum 0.5A)  PCB 
F2 ‐ fuse (maximum 15A) Over current 
J1 ‐ 1&2 MM1 Master gate 
J2 ‐ 3&4 SM2 Slave gate 
J3 ‐ 5&6 Electric lock, 12VDC, Max current 5A 
J3 ‐ 7&8 Flashing light. 12VDC, Max power 21W 
J4 ‐ 9 Positive Supply 12V DC  
J4 ‐ 10 use with 12 Keypad / Pushbutton for the dual gate operation 
J4 ‐ 11 use with 12 Keypad / Pushbutton for the single gate operation 
J4 ‐ 12 Logical and Power Ground for external devices 
J4 ‐ 13 Positive Supply 12V DC  
J4 ‐ 14&15 Photo sensor contacts, must be shorted together if no photocell 
J5 ‐ 16 Aerial Antenna cable (Connect to Aerial for increased range) 
J6 ‐ Reset Switch 
SW2 ‐ This button is used for code learning. 
VR1 ‐ Over current limit can be adjusted from min 3.5Amp to Max 7.5Amp 
VR2 ‐ Close delay can be adjusted from min 0 second to Max 8 second 
 