8. Electrical Installation 
 
8.1 ‐ Connecting the AC Power 
The control box should be equipped with a single‐phase breaker (15A). Make sure that the 
power is OFF before making any electrical connections. Remove the cover of the control box, 
perform the wiring and replace the cover again. 
 
Wire your AC line into the AC IN terminal at the top of the control box near the transformer.   
Wire the ground (usually green) to the terminal on the left. 
Wire the hot (usually black) wire to the middle terminal. 
Wire the neutral (usually white) wire to the terminal on the right.  
 
Verify that all electrical connections are waterproof by installing electrical outlets into exterior 
grade boxes with waterproof covers. Make sure that whenever an electrical connecter enters 
or exits a box it is sealed.  If using solar, verify that all connections are waterproof.  Please 
Note the system cannot execute the learning mode (remote control) by battery power only.  
Once your breaker is activated, the LED should light. 
CONTROL BOX DIAGRAM