Advanced Control Wiring

This picture details the Control Board. It identifies each of the items you will need
during the installation of the Gatekeeper YG.
The jumper numbers on the main board are named to help illustrate the connections that
will be made.
The information below details the connections used during installation:
F1 - fuse (maximum 0.5A) PCB
F2 - fuse (maximum 15A) Over current
SW2 - Used to program the remote controls to the board.
VR1 - Over current limit can be adjusted from min 3.5Amp to Max 7.5Amp
VR2 - Close delay can be adjusted from min 0 second to Max 8 second
Refer to the Control Board picture above. The lower row of items in the drawing support
additional items that can be added to the Control Board. Each auxiliary item is explained
in the text that follows the drawing.