8.2 ‐ Wiring the Battery (see Fig.7b) 
Inside the control box, connect the red battery lead to 'BAT+' terminal of control 
board, and black battery lead to 'BAT‐'. Use terminal J8 for the battery. 
 
 
Definition of flashing light codes
 
Quick flashing light 
Normal flashing light 
Slow flashing light 
Lamp  fixed  light  7  sec 
without gate movement 
 
8.3 ‐ Wiring the Actuators 
Connect the wires from the master or number one gate actuator to the MM1 
terminals 1& 2 on the control board.  Connect the wires from the slave or number 2 
gate actuator into the SM2 terminals 3 & 4 on the control board.  If using a single gate 
only, then connect the single actuator to MM1 only. 
 
Make sure that the actuators are mounted so that when activated they will close, 
i.e. mount the actuators so that the gate is open (actuators are retracted). 
 
Battery
RED WIRE TO POSITIVE+
BLACK WIRE TO POSITIVE-
Figure 7b. 
Systems  operation  is  at  slow  down  speed  or  the  system  is  in 
learning mode / kickback / extra‐push phase. 
System is operating at the full speed. 
Gate is waiting for auto close execution. 
Gate is in a waiting mode since the photocell has been covered 
by obstacle during the gate closing or opening. 