8.2 ‐ Wiring the Battery (see Fig.7b)
Inside the control box, connect the red battery lead to 'BAT+' terminal of control
board, and black battery lead to 'BAT‐'. Use terminal J8 for the battery.
Definition of flashing light codes
Quick flashing light
Normal flashing light
Slow flashing light
Lamp fixed light 7 sec
without gate movement
8.3 ‐ Wiring the Actuators
Connect the wires from the master or number one gate actuator to the MM1
terminals 1& 2 on the control board. Connect the wires from the slave or number 2
gate actuator into the SM2 terminals 3 & 4 on the control board. If using a single gate
only, then connect the single actuator to MM1 only.
Make sure that the actuators are mounted so that when activated they will close,
i.e. mount the actuators so that the gate is open (actuators are retracted).
Battery
RED WIRE TO POSITIVE+
BLACK WIRE TO POSITIVE-
Figure 7b.
:
Systems operation is at slow down speed or the system is in
learning mode / kickback / extra‐push phase.
System is operating at the full speed.
Gate is waiting for auto close execution.
Gate is in a waiting mode since the photocell has been covered
by obstacle during the gate closing or opening.
17