12. Auto-reverse function
It is very important that you tune the safety reverse function on your gate 
opener.  Power the control box if it is not already and verify that you have completed 
the remote programming exercise and self learning.  When properly adjusted, the 
gate should close and stop when it hits the stop block without overly forcing the 
gate, and reverse if it strikes an object before it reaches its stop.  An alarm should 
sound if it activates the auto‐reverse.   
Use a screw driver to rotate the Over Current Adj. knob.  Rotating clockwise will 
increase the resistance needed to trip the safety reverse function.  Rotating counter‐
clockwise will decrease the resistance.   
If the gate does not move when activated, or auto‐reverses without striking an 
obstacle, then the resistance setting may be too little.  If the gate does not stop when 
an obstruction is placed in its path, then the setting may be too high.  Start with just 
above the minimum value, and tune it to use the minimum setting for which the gate 
will function.   
WARNING:  Do not attempt to tune the gate by placing your hand, arm or other 
body part in the path of the gate. This could result in serious injury.  Also placing a 
heavy immovable object in the path to test with could cause damage to the gate 
opener motors.  Instead, place a light object in the path, preferably something like a 
chair or trash can which will be pushed out of the way if the setting is still too high 
without causing damage to the gate motors.  Note, this auto‐reverse function should 
be regularly inspected and adjusted if necessary.  Once this step is complete, replace 
the cover and install the rubber caps over the screws. 
 
 
OVER CURRENT SENSITIVITY:   
The  limit  of  Over‐Current  can  be  adjusted  from  Min 
3.5Amp to Max 7 Amp. 
 
 
 
 
 
 
 
 
 
CLOSE  DELAY:  The  time  for  the  SM2  (slave  leaf)  start 
delay for gate closing can be adjusted from Min 0 second 
to Max 8 second. 
 
 
25