16. Maintenance & Troubleshooting 
Battery overheating 
The gate doesn't work after 
pressing remote control. 
Motor speed is slower than 
expected. 
The gate stopped during the 
operation (opening or closing). 
The gate doesn't work or the 
gate works only in one direction.
Check  the  wiring  of  the  battery  and  make 
sure that it is well connected and using the 
correct polarity. 
1. Check  if  the  LED  used  for  "SLOW 
DOWN / POWER" is lighted. 
2. Check if the voltage of the battery is less
than 10.5 VDC. 
3. Check  the  LED  used  for  "push  button" 
is lighted. 
 
Turn  the  power  off  (disconncect  J7/J8) 
for  30  seconds,  then  turn  it  back  on  and 
repeat the learning process. 
4. Check to see if the fuse is burned out. 
1. Check to see if the gate stopped because 
of the push button, photo sensor, or over 
current (obstruction). 
2. Check to make sure that the battery and 
transformer J7/J8 is well connected. 
1. Check to make sure that the Reset switch 
is  on,  and  that  the  reset  switch  is  well 
connected with terminal J6. 
2. Adjust  the  VR1.  Re‐set  the  over  current 
limit at the proper position.  
3. Check  the  wiring  of  the  motor  is  well 
connected. 
4. Check  that  the  jumper  for  the  photocell 
is  in  place  or  that  the  IR  Photo  Safety 
Sensor is in place and functioning. 
5. Check to see if the fuse is burned out. 
1. Check to make sure that the Reset switch 
is  on,  and  that  the  reset  switch  is  well 
connected with the terminal J6. 
2. Check  that  the  wiring  of  the  motor  is 
well connected. 
3. Check  that  the  jumper  for  the  photocell 
is  in  place  or  that  the  IR  Photo  Safety 
Sensor is in place and functioning. 
28