Pedestrian Start Feature:
The System can open only one side of the gate for pedestrian
traffic:
For a dual gate, connect the motor cables for both terminals J1 & J2.
Press the green button of the transmitter to activate Pedestrian
Start.
For single gate, connect the motor cable for terminal J1 only. Press
the black button of transmitter to activate Pedestrian Start.
15. Operation Notes on the Gate Opener System
When the gate is travelling at normal speed, if the motor encounters an over current
condition (because of obstruction), the gate will stop immediately in opening phase but
for the closing phase, the gate will stop and reverse back for approx. 2 sec.
If any command (transmitter, keypad or photocell or other abnormal case) interrupts the
leaf's motion before it moves to the end of travel, the gate can only be operated with slow
down speed for the rest of the cycle. The function is guaranteed for the maximum safety
during the operation.
Kickback / extra–push
This is usually employed to help the electric lock insertion and release during
bad weather conditions (wind, ice, etc.).
Open / Closing delay
SM2 (slave motor) delay at opening
System is designed for a fixed time delay (about 3 seconds) between the
first gate (MM1) and the second gate (SM2) during the gate opening
phase.
MM1 (Master motor) delay at closing
Delay time can be adjusted from Min 0sec to 15sec.
Automatic mode
At the end of pause period, the gate will close automatically but if a new
command (transmitter, keypad, photo sensor or over current) is supplied before
the end of travel, this new command will cause the gate to reverse its motion.
Stop (Reset): If the reset switch is off, the gate systems will not work.
SLOW DOWN SPEED: The final speed can be
set when the gate is moving at slow‐down speed
ON: The final speed = 55% normal speed.
OFF: The final speed = 70% normal speed.
27