Operation Notes On The Gate Opener System - Gatekeeper YG-5602/1U/E Owner's Manual

Hide thumbs Also See for YG-5602/1U/E:
Table of Contents

Advertisement

 
Pedestrian Start Feature: 
The System can open only one side of the gate for pedestrian 
traffic: 
For a dual gate, connect the motor cables for both terminals J1 & J2.  
Press the green button of the transmitter to activate Pedestrian 
Start. 
For single gate, connect the motor cable for terminal J1 only.  Press 
the black button of transmitter to activate Pedestrian Start. 
 
15. Operation Notes on the Gate Opener System 
 
When the gate is travelling at normal speed, if the motor encounters an over current 
condition (because of obstruction), the gate will stop immediately in opening phase but 
for the closing phase, the gate will stop and reverse back for approx. 2 sec.  
 If any command (transmitter, keypad or photocell or other abnormal case) interrupts the 
leaf's motion before it moves to the end of travel, the gate can only be operated with slow 
down speed for the rest of the cycle.  The function is guaranteed for the maximum safety 
during the operation. 
Kickback / extra–push 
This  is  usually  employed  to  help  the  electric  lock  insertion  and  release  during 
bad weather conditions (wind, ice, etc.). 
Open / Closing delay 
SM2 (slave motor) delay at opening 
System is designed for a fixed time delay (about 3 seconds) between the 
first gate (MM1) and the second gate (SM2) during the gate opening 
phase. 
MM1 (Master motor) delay at closing 
Delay time can be adjusted from Min 0sec to 15sec. 
Automatic mode 
At the end of pause period, the gate will close automatically but if a new 
command (transmitter, keypad, photo sensor or over current) is supplied before 
the end of travel, this new command will cause the gate to reverse its motion. 
Stop (Reset): If the reset switch is off, the gate systems will not work. 
SLOW  DOWN  SPEED:  The  final  speed  can  be 
set when the gate is moving at slow‐down speed   
ON: The final speed = 55% normal speed. 
OFF: The final speed = 70% normal speed. 
 
 