Installation of indoor unit

Step one: choosing installation location
Step two: install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
       plastic  expansion  particles  in  the  holes.
3. Fix  the  wall-­mounting  frame  on  the  wall  with  tapping  screws  (ST4.2X25TA)  and
Step three: open piping hole
1. Choose  the  position  of  piping  hole according  to  the  direction  of  outlet  pipe. The
position  of  piping  hole  should  be  a  little lower  than  the  wall-­mounted  frame,
shown  as  below.
QB:
9K
Wall
Mark  in  the  middle  of  it
Space
to  the
wall
above
150mm
Left
Φ55mm
Rear  piping  hole
QD:
18K
Wall
Mark  in  the  middle  of  it
Space
to  the
wall
above
150mm
Left
Φ55mm
Rear  piping  hole
2. Open  a  piping  hole  with  the  diameter  of  Φ55  or  Φ70  on  the  selected  outlet
pipe  position.In  order  to  drain  smoothly,  slant  the  piping  hole  on  the  wall  slightly
downward  to  the  outdoor  side  with  the  gradient  of  5-­10°.
Wall
Level  meter
Space
to  the
wall
above
150mm
Right
Φ55mm
Rear  piping  hole
Wall
Level  meter
Space
to  the
wall
above
150mm
Right
Φ55mm
Rear  piping  hole
32
29
QC:
12K
Wall
Mark  in  the  middle  of  it
Space
to  the
wall
above
150mm
Left
Φ55mm
Rear  piping  hole
22K
QE:
Wall
Mark  in  the  middle  of  it
Space
to  the
wall
above
150mm
Left
Φ70mm
Rear  piping  hole
rm  it  with  the  client.
.
Wall
Level  meter
Space
to  the
wall
above
150mm
Right
Φ55mm
Rear  piping  hole
Wall
Level  meter
Space
to  the
wall
above
150mm
Right
Φ70mm
Rear  piping  hole