Indoor Unit Installation - Whirlpool SLIM RANGE R22 Instructions For Use Manual

Slim range single split air conditioner with ecological gas r407c and with gas r22
Table of Contents

Advertisement

33933049GB.fm Page 18 Monday, January 10, 2005 5:27 PM

Indoor unit installation

1. Installing the Mounting Plate
Select a location to install the mounting plate according to the indoor
unit location and piping direction.
Adjust the mounting plate horizontally with a horizontal ruler or
plumb line.
Drill holes 32 mm deep on the wall to fix the plate.
Insert the plastic plugs in the hole, then fix the mounting plate with
tapping screws.
Check that the mounting plate is well fixed. Then drill a hole for the
piping.
NOTE:
The shape of your mounting plate may be different from the one
above, but installation method is similar.
2. Drill a Hole for Piping
Decide the position of the hole for piping according to the location of
the mounting plate.
Drill a hole on the wall. The hole should slightly be inclined downward
toward outside.
Install a sleeve through the wall hole to keep the wall tidy and clean.
3. Indoor Unit Piping Installation
Fit the piping (liquid and gas pipe) and cables through the wall hole
from outside or fit them from inside after completing indoor piping
and cables connections so as to connect to outdoor unit.
Decide whether to saw off the plastic part in accordance with the
piping direction (as shown below).
NOTE:
When fixing the pipe along directions 1, 2 or 4, saw the
corresponding plastic part off the indoor unit base.
After connecting the piping as required, install the drain hose. Then
connect the power cords. After connecting, wrap the piping, cords
and drain hose together with thermal insulating materials.
IMPORTANT:
Piping Joints Thermal Insulation:
Wrap the piping joints with thermal insulating materials and then
cover with vinyl tape.
18
Hook the line here
Line drops from here
Mounting
Plumb line
plate
Holes for fixing
Wall hole sleeve
(hard polythene tube
prepared by user)
5 mm
(downward
inclination)
Piping direction
trough
Plastic
part
Saw off the plastic
part along the
trough
Thermal insulation
wrapped with vinyl tape

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Slim range r407c