Type Tests And Environmental Conditions; Type Tests And Environmental Conditions - Advantech ICR-3241 User Manual

Lte industrial
Hide thumbs Also See for ICR-3241:
Table of Contents

Advertisement

7.3 Type Tests and Environmental Conditions

Phenomena
ESD
RF field AM
modulated
Fast transient
Surge
RF conducted
Radiated emission
Conducted
emission
Dry heat
Cold
Dump heat
Vibration
Shock
LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: info@lucom.de — www.lucom.de
Test
Description
EN 61000-4-2
Enclosure contact
Enclosure air
EN 61000-4-3
Enclosure
EN 61000-4-4
Signal ports
Power ports
Ethernet ports
EN 61000-4-5
Ethernet ports
Power ports
EN 61000-4-6
All ports
EN 55032
Enclosure
EN 55032
DC power ports
Ethernet ports
EN 60068-2-2
+75 C *, 40 % rel. humidity
MIL-STD-810G
SAE J1455
EN 60068-2-1
-40 C *
MIL-STD-810G
SAE J1455
EN 60068-2-78
95 % rel. humidity (+40 C)
MIL-STD-810G
SAE J1455
EN 60068-2-64 ed. 2
Vibration spectrum
MIL-STD-810G
A.3 (rolling stock)
SAE J1455
EN 60068-2-27 ed. 2
half-sine, 50 g peak, 11 ms
MIL-STD-810G
SAE J1455
Table 16: Type tests and environmental conditions
29
ICR-3241
Test levels
6 kV (crit. A)
8 kV (crit. A)
10 V/m (crit. A)
(80 – 2700 MHz)
3 V/m (crit. A)
(2700 – 6000 MHz)
1 kV (crit. A)
2 kV (crit. A)
1 kV (crit. A)
1 kV (crit. A), shielded cab.
0,5 kV (crit. A)
10 V/m (crit. A)
(0,15 – 80 MHz)
Class B
Class B
Class B
Category 1 (3 axis, 8 hours
per axis)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icr-3241wIcr-3241-1ndIcr-3241w-1nd

Table of Contents