7.3 Type Tests and Environmental Conditions
Phenomena
ESD
RF field AM
modulated
Fast transient
Surge
RF conducted
Radiated emission
Conducted
emission
Dry heat
Cold
Dump heat
Vibration
Shock
LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: info@lucom.de — www.lucom.de
Test
Description
EN 61000-4-2
Enclosure contact
Enclosure air
EN 61000-4-3
Enclosure
EN 61000-4-4
Signal ports
Power ports
Ethernet ports
EN 61000-4-5
Ethernet ports
Power ports
EN 61000-4-6
All ports
EN 55032
Enclosure
EN 55032
DC power ports
Ethernet ports
EN 60068-2-2
+75 C *, 40 % rel. humidity
MIL-STD-810G
SAE J1455
EN 60068-2-1
-40 C *
MIL-STD-810G
SAE J1455
EN 60068-2-78
95 % rel. humidity (+40 C)
MIL-STD-810G
SAE J1455
EN 60068-2-64 ed. 2
Vibration spectrum
MIL-STD-810G
A.3 (rolling stock)
SAE J1455
EN 60068-2-27 ed. 2
half-sine, 50 g peak, 11 ms
MIL-STD-810G
SAE J1455
Table 16: Type tests and environmental conditions
29
ICR-3241
Test levels
6 kV (crit. A)
8 kV (crit. A)
10 V/m (crit. A)
(80 – 2700 MHz)
3 V/m (crit. A)
(2700 – 6000 MHz)
1 kV (crit. A)
2 kV (crit. A)
1 kV (crit. A)
1 kV (crit. A), shielded cab.
0,5 kV (crit. A)
10 V/m (crit. A)
(0,15 – 80 MHz)
Class B
Class B
Class B
Category 1 (3 axis, 8 hours
per axis)